Rear vent Flue Installation
1. Determine the exact location for the heater.
2.
Mark the exact location for the wall penetration
a.
Determine that you will not be cutting through any vertical wall studs.
b.
Check that the location of the wall-mounted terminal conforms to the requirements of
AS/NZS 5601 – Location of a Flue Terminal.
3.
Cut 2 holes 95mm in diameter at 100mm centres holes to be side by side in the horizontal.
4.
Use the back of the cowl as a template for fixing holes.
5.
Fit flex flue to spigots on the rear of the cowl using provided hose clamps and seal with
silicone.
NOTE- it may be necessary to trim the flue depending on wall thickness.
6. Attach the back of the cowl to the wall. Silicone around outside.