CHATEAU GAS VALVE
SIT 843
“
A
” represents the low gas adjustment. Turn the screw clockwise to increase gas pressure.
“
B
” represents the high gas adjustment. Turn the nut clockwise to increase gas pressure.
Natural Gas
Burner test point pressure –
HIGH
1.0 kPa
, LOW
0.48 kPa
Primary air shutter adjustment –
fully open
Natural gas injector orifice –
2.8mm diameter
LPG Gas
Burner test point pressure -
HIGH
2.60 kPa
, LOW
1.30 kPa
Primary air shutter adjustment –
fully open
Propane gas injector orifice –
1.6 mm diameter