35
COOLIUS Y50A
Vacuum
1. Turn
COOLIUS SELECT
to set the vacuum time.
• Minimum:
20 min.
• Maximum:
900 min.
2. Press
ENTER
to confirm.
3. Turn
COOLIUS SELECT
to set the leak test time.
• Minimum:
2 min.
• Maximum:
60 min.
4. Press
ENTER
to confirm.
A/C system charge
A) In case of vacuum selected:
1. Turn
COOLIUS SELECT
to select the oil type (PAG oil
or POE oil).
Press
ENTER
to confirm.
1. Turn
COOLIUS SELECT
to set the Fresh oil value.
NOTE:
The value indicates only the new oil added to the
drained oil.
• Minimum:
0 g.
• Maximum:
150 g.
2. Press
ENTER
to confirm.
3. Turn
COOLIUS SELECT
to set the refrigerant amount.
• Minimum:
50 g.
4. Press
ENTER
to confirm.
B) In case of vacuum not selected:
C) In case of A/C system charge:
5. Turn
COOLIUS SELECT
to set (usually HP).
HP Port
/
LP Port
/
HP/LP Port
6. Press
ENTER
to confirm.
7. Input CAR DATA, then press
START
key to confirm.
The equipment performs all the selected processes.
At the end The machine performs a self-cleaning process
See chapter 4.6 Automatic Internal flushing
if “Automatic internal flushing” is activated under
Machine Set-up
Otherwise it goes to stand-by mode.
Vacuum time
min. 20
Leak test min. _
Select oil type:
PAG oil
PAG Oil ml. 10
UV Dye ml. _
Refrigerant
g._____
Refrigerant
g._____
Charge A/C system by
HP PORT