20
COOLIUS Y50A
4.5.3 Company data
Turn
COOLIUS SELECT
to select
Company data
.
Press
ENTER
to confirm.
5 lines are available:
1_________
Company name (Workshop)
2_________
Address (road, etc..)
3_________
City
4_________
Phone
5_________
FAX
The above setting is an example only.
NOTE:
The five lines are reported on the service report.
Procedure:
• Turn
COOLIUS SELECT
to select the character.
Press
ENTER
to confirm.
The character is reported on the first line (left).
• If required, press
X
key to delete.
• It is possible to move in the line by
LEFT / RIGHT
• Turn
COOLIUS SELECT
to select the next character.
Press
ENTER
to confirm.
The character is reported on the first line.
• Press
START
key to confirm the setting.
The display shows the following line.
• Press
STOP
when the 5 lines are set.
1_________
C
567890 AB DEFGHIJKLM
4.6
Automatic Internal flushing
The machine is equipped with two oil bottles (one for the PAG oil and one for POE oil). Due to low compati-
bility between the two kinds of oil, it is strongly suggested to avoid the mixing between the two.
In order to avoid contamination, the Automatic Internal flushing function performs a machine cleaning phase
at the end of each process involving the oils.
This function can be deactivated if sure that only one type of oil is used with the machine (also in case of
recovery!).
IMPORTANT NOTE:
Excluding this function may cause anomalies in the A/C system and could
create hazardous situations for the user (electric shocks on the A/C compressor unit)
At the end of Vessel Charge, A/C Pressure Test, A/C Data-
Base, Full Service, Open Program (only the ones including
“Recovery” and/or “A/C System Charge”), the display shows:
Perform the instruction, then press
START
key to confirm.
At the end of the process:
Press
STOP
key to exit.
Join HP/LP couplers
to the stands and
Open the valves
Internal flushing
end
Machine ready!