28
COOLIUS Y50A
5.2 Full service
1. Press
ENTER
to go to selection menu (if in Stand-by
mode).
2. Turn
COOLIUS SELECT
to select
Full Service
.
3. Press
ENTER
to confirm.
4. Turn
COOLIUS SELECT
to set the amount of refrigerant
to be charged into the A/C system.
• Minimum: 50 g.
5. Press
ENTER
to confirm.
6. Turn
COOLIUS SELECT
to set
Automatic / Manual / NO
Press
ENTER
to confirm.
If
Automatic
or
Manual
is selected, then the display
shows:
7. Turn
COOLIUS SELECT
to set
PAG Oil
or
POE Oil
Press
ENTER
to confirm.
If
Automatic
is selected, then the display shows:
8. Turn
COOLIUS SELECT
to set oil quantity,
confirm by
ENTER
,
then set UV quantity and press
ENTER
to confirm.
9. Turn
COOLIUS SELECT
to set (usually HP)
HP PORT / LP PORT / HP/LP PORTS
Press
ENTER
to confirm.
See chapter 4.2 Using the printer
10. Press
START
key to confirm.
The equipment performs all the processes.
• Refrigerant test.
• Recovery.
• Residual refrigerant check.
• Used oil drain process.
• Nitrogen Pressure test
(if Nitrogen Press.Test AUTO is set to
1
in
Machine Set-up
).
•
Vacuum, Leak test.
• New oil charge.
• UV Dye charge.
• Refrigerant charge.
Full service
Refrigerant g. 500
Oil/UV charge
Automatic
Select Oil Type
PAG Oil
PAG Oil ml. _
UV dye ml. _
Charge A/C system by
HP PORT
Confirm by “START“