27
COOLIUS Y50A
5 Programs
5.1 New oil bottle change
NOTE:
A/C System can be damaged.
If it is required to change the kind of compressor oil, the A/C machine will require flushing to
prevent cross contamination of oils. This procedure cleans the hoses and pipes prior to new oil
injection.
1. Turn
COOLIUS SELECT
to select
Other selections
.
Press
ENTER
to confirm.
2. Turn
COOLIUS SELECT
to select
New oil bottle change
.
Press
ENTER
to confirm
3. Turn
COOLIUS SELECT
to select the bottle that has to
be replaced (PAG oil or POE oil).
Press
ENTER
to confirm.
4. Replace the oil bottle with the new oil bottle.
Press
ENTER
to confirm.
5. Perform the instruction.
Press
START
key to confirm.
6. The machine starts.
If the couplers are not joint to the stand or the coupler valves
are not closed, message:
Press
START
key to confirm.
The machine starts.The process cleans the complete
unit included the service hoses.
At the end:
Press
STOP
key to exit.
The machine is ready.
New oil bottl.change
Select oil type:
PAG oil
Replace oil bottle
with the new oil
bottle for specific
application.
Join HP/LP couplers
to the stand and
open the valves!
Confirm by “START“
Internal flushing
Wait!
Join HP/LP couplers
to the stand and
open the valves!
Confirm by “START“
Internal flushing