Cool Energy EcoStore Manual v3.2 2020 © 

 

 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

 

 
 
 
 

 

Eco

Store  

                                                                                 

 

 

 

 

Summary of Contents for EcoStore CE-ES200

Page 1: ...Cool Energy EcoStore Manual v3 2 2020 EcoStore ...

Page 2: ...to the current technological level Please always refer to the instructions contained in this manual when installing the equipment The operations described in these instructions require specialized knowledge achievable through a comprehensive and proven professional training in system installation As a consequence we recommend that you only perform the installation operations described herein if yo...

Page 3: ... 09 2 4 MAIN COMPONENTS 10 2 4 1 TANK 10 2 4 2 HEAT PUMP UNIT 10 2 4 3 ANTI CORROSION PROTECTION 10 2 4 4 THERMAL INSULATION AND COATING 10 2 5 DIMENSIONAL CHARACTERISTICS 11 TECHNICAL DATA TABLE 12 3 INSTALLATION AND FIRST START UP 13 3 1 HYDRAULIC CONNECTION 14 3 1 1 HYDRAULIC SAFETY UNIT 15 3 1 2 PRESSURE REDUCER 15 3 1 3 EXPANSION TANK 15 3 2 UNIT FILLING 15 3 3 DUCT 17 3 4 ELECTRICAL CONNECTI...

Page 4: ... 28 4 10 FAQ 29 4 11 HYDRAULIC SAFETY UNIT EFFICIENCY CHECK 31 4 12 UNIT EMPTYING 31 4 13 RESTART AFTER A LONG TERM STOP 31 5 MAINTENANCE INSTRUCTIONS 32 5 1 GENERAL 32 5 2 FALSE ERRORS OF OPERATION 32 5 3 VISUALIZED TEMPERATURE 32 5 4 HEAT PUMP UNIT MAINTENANCE 33 5 5 CLEANING THE ASPIRATION AIR FILTER 33 5 6 WATERCIRCUIT CONDENSATE DISCHARGE 33 5 7 AIR CIRCUIT SUPPLY 34 5 8 DESCALING AND LIMESCA...

Page 5: ......

Page 6: ...cified in the relevant paragraph the supplied nylon electricalprotectors must be properly installed the hydraulic safety unit must be properly installed intact and in good working order installation and maintenance must be performed by qualified personnel in compliance with the building regulations in force before starting any maintenance or repair operations on components containing any cooling f...

Page 7: ...pump for sanitary water show any clear damages absolutely avoid mounting or installing it Immediately inform the supplier 1 7 Transport When storing and transporting it always keep the heat pump water heater vertical straight in its original packaging For short stretches it can be inclined by 45 provided utmost care is taken when transporting it Due to the forward inclination when using forklift t...

Page 8: ...e relevant physical magnitudes are those of the International System SI 1 9 Temperature unit shift Press ENTER for 3 seconds to unlock the buttons Long pressing the E HEATER key for 10 seconds they can shift the temperature from display unit from F to C or from C to F The default is C When it is shifted to display F it still will display C while it operates spot check ...

Page 9: ...state as a consequence of thermal dissipation The liquid refrigerant flowing through a choking component expansion valve undergoes a low pressure expansion dilatation and after returning to the evaporator it can again draw heat from the surrounding environment The hot water heat pump operates at ambient temperatures ranging between 20 C and 43 C The hot water heat pump is a connection ready equipm...

Page 10: ...emperature target range 38 65 C Using renewable energies and ensuring optimum energy efficiency the heat pump for sanitary water provides an environment friendly and cheap solution to heat water all over the year 2 4 Main components 2 4 1 Tank The tank consists of a water tight unvented cylindrical inner vessel Cylinder material inox AISI316L 2 4 2 Heat pump unit The refrigerant circuit is located...

Page 11: ...x 105 C Protection cable flat cable 2x0 50mm red black red cable electrode electrode connection bush diam 3mm tank connection eyelet diam 5mm Positioning All fastenings connections and maintenance operations must be performed when the device is not powered or in use Be sure that the device is properly positioned far away from water direct heat sources etc Do not open the cover of the device there ...

Page 12: ...istics of the equipment are indicated in Fig 1 The electrical characteristic data of each model can be found on the equipment itself Model Diameter Ø Height Weight EcoStore 200 650mm 1586mm 101kg EcoStore 300 2107mm 118kg Heating exchanger surface Model Unit Lower heating exchanger EcoStore 200 m2 0 6 EcoStore 200 1 3 ...

Page 13: ... TCO1 TCO2 de frosting automatic Air flow M3 h 414 Compressor Oil Type PAG Heating up time h min 4 10 6 21 Heating up energy input kW 2 48 3 7 Standby power input W 32 32 Total useful energy Q lp kWh 11 6 19 1 Total energy consumption W el p kWh 3 55 5 26 Reference Hot Water θ wh C 53 34 53 3 Rated Heat Pump Output kW 1 527 1 527 COPDHW Tapping Cycle 20 55c from EN16147 3 28 3 63 ErP Test Profile ...

Page 14: ...mperature settings 55 C 55 C Sound power level indoor Lwa 59 dB A 59 dB A Precautions for installation and maintenance Read precautions for installation and maintenance at specific chapters on user s and installation s manual TECHNICAL PARAMETERS ACCORDING TO REGULATION EU No 814 2013 MODELS EcoStore 200 EcoStore 300 Daily electricity consumption Qelec Indoor air 20 C 4 36kWh 4 15kWh under warmer ...

Page 15: ...varnish removers refrigerants and many other commercial and household products In addition excessive dust and lint may affect the operation of the unit and require more frequent cleaning 9 The external air temperature must be above 7ºC and below 43ºC If the external air temperature falls outside these upper and lower limits the electrical element will be activated to meet the hot water demand 10 D...

Page 16: ...ce If possible install the equipment in a room allowing to exploit the excess heat generated by tumble driers refrigerators freezers etc Air must be neither excessively purified nor too contaminated with dust There must be ablack waterdrain with a syphon to eliminate condensation CAUTION The equipment is not intended to be used by any persons including children having reduced sensory or mental fac...

Page 17: ...Temperature Pressure relief valve to cylinder Expansion vessel Tundish The above components are required to safely run the supplied equipment The rated calibration pressure of the temperature and pressure relief valve must be of 0 6 MPa 6 bar Pay attention while installing the safety components avoiding forcing or alteration You need to install a discharge pipe with a constant downward slope in a ...

Page 18: ...t filling WARNING Switching on the equipment when it is not filled with water will seriously damage the refrigerating units and the electrical heating element WARNING In the presence of water with a hardness degree 20 TH where 1 TH French degree 10mg CaCo3 l it is mandatory that you install a softener to reduce limestone scaling inside the boiler and keep the electrical resistance and the hydrauli...

Page 19: ... of bending should be no more than 3 For unit air outlet with duct when unit operating condensate will be generated around outside of duct please pay attention to the drainage work we suggest wrapping the thermal insulated layer around outside of the duct It is recommended to install the unit in an indoor space it is not allowed to install the unit where it can be rained on WARNING In case of rain...

Page 20: ...you need to use a two pole switch complying with the EN standards contact opening 3mm preferably equipped with fuses The connection must be established by inserting the plug into the appropriate outlet or hard wired to a switch Connections must comply with BS7671 2018 or the regulations in force WARNING Switching on the equipment when it is not filled with water will seriously damage the refrigera...

Page 21: ...e electrical connections are correct also check that the tank is filled with water to avoid seriously damaging the refrigerating unit and the electrical heating elements 4 2 Electronic control The heat pump water heater is equipped with an electronic control system for the management of the temperature and of the supplementary E Heater 4 2 1 Display ...

Page 22: ...er disinfect mode otherwise it will be extinguished It will be lightened if disinfect mode is automatically activated by unit It will flash with 1Hz frequency if disinfect mode is manually activated It will flash with 2Hz frequency when setting disinfect mode or setting disinfect timer 7 High temp Alarm If setting water temp is higher than 50 C it will be lightened otherwise it will be extinguishe...

Page 23: ...ons before turning on the product When the product is turned on for the first time all indicators on the UI will turn on for 3 seconds and at the same time an acoustic sound will be heard After a minute without any other operation all buttons are blocked apart from UNLOCK button Press it for 3 seconds to unlock the buttons When the tank is filled and all the settings set press the ON OFF button an...

Page 24: ...eater as the backup heat source but the code E7 and will be shown until power off Note If only the electric element is used as a heating source only one part of the cylinders content will be heated the water temperature must be set at a higher value that the one for the running of the heat pump Defrosting during water heating In the heat pump running period if the evaporator frosted in lower ambie...

Page 25: ...k sign Lock indicator lights up When the unit is locked no keys can be operated Press for 3 second to unlock the button 4 4 5 Query function For the convenience of maintenance and debugging the query function is available by Pressing 2 buttons together then system running parameters will be shown one by one with following sequence by each pushing of o button N TEMP DASYS EXPLENATION 1 t 5 U Temp T...

Page 26: ...to set the time for accurate local time Every time powered off the clock will be reset to initial time 00 00 Method for time set Press button for 5 sec to enter clock setting Then icon will be lightened and the hour value of clock will flash slowly Set the hour value of clock Confirm the hour setting Then the minute value of clock will flash slowly Set the minute value of clock Confirm the minute ...

Page 27: ...wly Set the minute value of timer Confirm the minute value of timer Then ON or OFF icon following the setting timer will flash slowly Set the action ON or OFF of the timer Confirm the action ON or OFF of the timer ON OF ON OFF The display screen will automatically display different valueat by different action It will display the last set temperature and icon if the action is ON and will display if...

Page 28: ...or check timer setting Select time which needs to be checked The timer icon will flash slowly if it is selected and the timer action ON or OFF and set clock will be shown If the action is ON target temperature will be shown And if the action is OFF icon will be shown Press button for 3sec or no button pressing for 30sec to quit timer checking If there is conflict between Timer Setting and Manual O...

Page 29: ...con flashes the icon lightens and the hour indicator starts to flash slowly Set the hour value of clock Confirm the hour setting Then the minute value of clock will flash slowly Set the minute value of clock Confirm the disinfect clock setting and quit out Unit will automatically start dis infect function at the above set clock every 7 days If user does not set dis infect clock unit will automatic...

Page 30: ...een under vacation mode or OFF press will lead to show invalid icon on the display 4 6 Combination button ICON DESCRIPTION Clear error code Press the two buttons at the same time to clear all stored error protect codes and the buzzer will buzz one time Query mode Press the two buttons at the same time for 1sec to go into query mode Under query mode user can check unit setting running parameters by...

Page 31: ...a qualified person to service the unit E2 Tank and Wired Controller communication error Maybe the connection between controller and PCB has released orPCB has been broken Contact a qualified person to service the unit E4 Evaporator temperature sensor T3 error Maybe the connection between sensor and PCB has released or sensor has been broken Contact a qualified person to service the unit E5 Ambient...

Page 32: ... 07 MPa inactive Maybe because of system blocked air or water or more refrigerant in system after repair water temperature sensor malfunction etc Contact a qualified person to service the unit P2 High discharge temperature protection Tp 115 C protection active Tp 90 C protection inactive Maybe because of system blocked air or water or less refrigerant leakage in system afterrepair water temperatur...

Page 33: ...upper part temperature D Why sometimes the temperature shown on the display decreased but unit still keep closed R To avoid unit ON OFF frequently unit will activate heat source only when bottom tank temperature is lower than setting temperature for at least 5 ºC D Why sometimes the temperature shown on the display will decreased dramatically R Because tank is pressure bearable type if there is ma...

Page 34: ...ollow the instructions provided by the manufacturer 4 12 Unit emptying Should the unit be going to remain unused for a prolonged time we recommend that you empty it In this case proceed as follows cut off the power supply and the main water supply open a hot water tap to allow air to flow in turn the drain valve at the lowest point to the open position 4 13 Restart after a long term stop When the ...

Page 35: ...2 False errors of operation Due to a start caused by a voltage drop you must wait 3 minutes before the reactivation of the compressor in order to preserve its integrity If the auto protection is activated and the system stops control that When the supply indicator is on if the system is being forced to function even without the normal operative conditions if the in out air flow is blocked or if a ...

Page 36: ...r and clean it from possible impurities Put again the cleaned filter and the opening before restart the equipment 5 6 Water circuit Condensate discharge The water circuit check is limited to the integrated filter installed by the customer if any in this case follow the instructions provided by the valve manufacturer also check the tightness of the valves and of the screw connections etc should the...

Page 37: ... water decreases The limestone deposits reduce the tank volume so also the transmission capacity of the heat exchanger and the production of hot water are reduced Maintenance must be done by qualified personnel For an accurate and competent maintenance of the inner tank it is necessary to have free access to the flange in order to control and clean the inner tank 5 9 Anode verification periodic Th...

Page 38: ...rth wire Disconnect the protection cable from the anode Remove and replace the anode Disconnect the electronic control from power connections Remove and replace the electronic control Restore the connection between electronic control and power Restore the earth wire connection Restore the connection of the protection cable with the anode Replace and fix the plastic cover Re fill the tank Verify th...

Page 39: ...ing abrasive products containing organic thinners alcohol benzine etc 5 12 General notes Always use tools that are appropriate for the intended purpose Always replace the gaskets and or the O rings to ensure the hydraulic sealing remains intact when replacing components Only use genuine spare parts When installing spare parts make sure that the resistance element is properly housed and the sealing...

Page 40: ...he water supply will be restored it will turn to normal The water pressure is too low Use the system when the pressure returns to normal The entry water valve is closed Open the entry water valve Water loss The hydraulic connections are not well sealed Control and seal all hydraulic connections The electrical resistance element makes noises Hard water grade is anomalous Water with lot of limestone...

Page 41: ...p water heater EN 41 P a g e 7 Illustrations Fig 1 Dimension LEGEND mod Ecostore KW cold water inlet WW hot water outlet PV heat exchanger inlet PR heat exchanger outlet Z recirculation K condensate drain pipe ...

Page 42: ...Heat pump water heater 42 P a g e Fig 2 Maintenance space requirements unit mm Recommended ...

Page 43: ...ection diagram Second Heat Source Fig 4 Hydraulic connection diagram Twin Coil Circuits SYMBOL LEGEND Interception valve Interception valve with retain device Pressure reduction Thermometer Manometer Condenses pipe Drain tap Safety valve Leak valve Pump Timer ...

Page 44: ...ater heater 44 P a g e Fig 6 Duct A Without ducting B Air outlet without conveyor air inlet connect to duct A 5m C Air inlet and outlet with duct A B 5m D Air outlet connect to conveyor air inlet without duct A 5m ...

Page 45: ...t a further use of the environmental energy Heat pump for hot waterwith connection to the air ducts outlet kit Through the heat released from the air the expelled air is cooled and can be used to refresh one or more rooms through the use of air ducts for example to refresh a wine cellar workshops during the summer period greenhouses etc a double energetic advantage with an optimal energetic effici...

Page 46: ...ons when using the heat pump 46 P a g e Heat pump for sanitary hot waterwith aspiration kit Heat pump for sanitary hot waterwith aspiration kit Heat pump for sanitary water with pellet boiler Heat pump for sanitary water with wall mounted gas boiler ...

Page 47: ... 47 Fig 6 Electric connection ...

Page 48: ... 48 ...

Page 49: ...ppliance will avoid potential health hazards and adverse consequences for the environment Recycling of materialshelpsto preserve natural resources For further information about the recycling of this appliance please contact your municipal offices your domestic waste disposal service or the retailer installer from whom the appliance was purchased The penalties for failure to comply with these dispo...

Page 50: ...art L of the Building Regulations Yes Type of control system if applicable Y Plan S Plan Other Is the cylinder solar or other renewable compatible Yes No What is the hot water temperature at the nearest outlet C All appropriate pipes have been insulated up to 1 metre or the point where they become concealed Yes UNVENTED SYSTEMS ONLY Where is the pressure reducing valve situated if fitted What is t...

Page 51: ... 51 ...

Page 52: ... 52 Cool Energy Holding Ltd 163 Cleethorpe Road Grimsby DN31 3AX Email sales coolenergyshop com www coolenergyshop com ...