Heat pump water heater
EN
38 |
P a g e
You must replace the anode in case of wrong working.
CAUTION: a wrong functionality of the anode reduces the last of the device.
In case of necessary substitution of the anode please do the following operations:
Procedure:
•
Switch off the device.
•
Disconnect the device from electrical supply
•
Drain the device (see par. 4.12) until the water level is lower than the height of anode
junction.
•
Unscrew the screws and remove the plastic cover.
•
Disconnect the earth wire
•
Disconnect the protection cable from the anode.
•
Remove and replace the anode.
•
Disconnect the electronic control from power connections.
•
Remove and replace the electronic control.
•
Restore the connection between electronic control and power.
•
Restore the earth wire connection.
•
Restore the connection of the protection cable with the anode.
•
Replace and fix the plastic cover.
•
Re-f
ill the tank.
•
Verify that there is no water leakage from joints.
•
Restore the connection to the electrical supply.
•
Switch on the device.
5.10 Replace and / or control the electrical resistance element
If the replacement of the electric resistance of integration is needed, follow the procedure here
described.