Error Messages and Remedies
Error
Message on display
Possible cause
Remedy
Water tap closed
Open water tap
Solenoid valve dirt filter
contaminated
Remove and clean filter
E01 Not
enough
water
Solenoid valve fault
Call customer service
E02 Connection
area
temperature too high
Connection area ventilation fault,
air supply blocked
Allow Combi to cool, or continue
cooking at a lower oven
temperature, and call customer
service
Motor temperature monitor triggered,
external failsafe triggered
Call customer service
E03 Fan
malfunction
Fan motor fault
Call customer service
E04 Connection
area
fan
malfunction
Auxiliary fan fault
Call customer service
E05
no gas
Gas supply interrupted
Open gas tap
Excess oven temperature
Call customer service
E11/E21
Excess temp. in oven/oven
sensor failure
Oven sensor fault
Call customer service
E13/E23
Excess temp. of steam
generator/steam gen.
sensor failure
Steam generator sensor fault
Call customer service
Water tap closed
Open water tap
Excess temperature in condenser via
hot water connection
Connect Combi to cold water,
restart
Solenoid valve dirt filter contaminated
Remove and clean filter
Solenoid valve fault
Call customer service
E15/E25
Excess temp. of condenser
/ condenser sensor failure
Condenser sensor fault
Call customer service
E22
Core temperature sensor
fault
Core temperature sensor fault
Set cooking program with time,
call customer service
E24
Bypass sensor failure
Bypass sensor fault
Call customer service
E26
Steam generator safety
temp. limiter sensor failure
Safety temp. limiter sensor fault in
steam generator
Call customer service
E27
Excess temperature of
Steam Generator heater
Steam generator dirtied
Descale steam generator
E29 Ground
connection
of
sensor
Temperature sensor fault
Call customer service
E33
Steam generator heater
error
Steam generator heater fault
Call customer service
E34
Steam generator pump
error
Steam generator pump fault
Call customer service
E80/E95/E96
ID error / software error /
connection fault
Control fault
Call customer service
E82
Working parameter error
Problems during switch between °C /
F
Check settings in Cookbook, or
check °C/F in Settings
Cleaner canister or nozzle rinsing fluid
agent empty
Fill canister
Low agent
pressure!
No cleaner pressure
Pump fault
Call customer service