5. TEST Temperature Probe:
a. Remove plastic tip protector from probe.
b. Replace probe in its hanger.
c. Set Temperature to 350° F in any cooking mode.
d. Set Probe Temperature to 210° F.
e. Begin cooking program.
f.
Display shows set (nominal) temperature on the left and probe temperature on the right.
g. Press Temperature to display the actual temperature.
h. When the actual temperature reaches 210° F the Signal Tone sounds and the Combi
turns off.