6. Exhaust Hood Requirements
a. Combi gas models MUST be installed under an exhaust hood.
b. Combi gas models equipped with the optional Flue Diverter (flue deflector) MUST be
installed under an exhaust hood.
Combi Models and Flue Diverter Part Numbers
Model OGB-6.10
OGS-6.10
OGB-6.20
OGS-6.20
OGB-10.10
OGS-10.10
OGB-10.20
OGS-10.20
OGB-12.20
OGS-12.20
OGB-20.10
OGS-20.10
OGB-20.20
OGS-20.20
P/N
C2616551 C2616564 C2616551
C2616567
C2616567
C2616571 C2616567
c. The exhaust hood must extend over the gas flue opening and meet the following requirements:
1) Combi gas models must be vented in accordance with all local, state and national
codes for venting gas fired appliances.
2) The exhaust hood must be sized for the cumulative ventilation requirements of all the
gas-fired appliances in the area under the hood, including the Combi.
3) If an existing hood cannot be used, a new one must be constructed over the Combi.
Model Number, BTU/HR, and Height, Depth, and Width in inches for calculating hood dimensions
and ventilation capacity requirements
.
Model OGB-6.10
OGS-6.10
OGB-6.20
OGS-6.20
OGB-10.10
OGS-10.10
OGB-10.20
OGS-10.20
OGB-12.20
OGS-12.20
OGB-20.10
OGS-20.10
OGB-20.20
OGS-20.20
BTU/HR 41,000 68,000 68,000 109,000 136,000 136,000 239,000
Height
34’’
36” 44” 44” 56” 77” 77”
Depth
32”
41” 32” 41” 42” 34” 42”
Width
37”
48” 37” 48” 49” 38” 49”
7. Combustible Air Supply
a. Keep all air intake vents clear, clean, and free of obstruction.
b. Observe all applicable codes for ventilation and combustion supply air.