[DI Status]
Choose Disable, NC, or NO according to your DI device (e.g., photo sensor).
z
Disable: Disable the DI function.
z
NC (normal closed): The signal loop is closed under normal conditions. When the loop
becomes open, DI will be triggered until the loop becomes closed again. In other words, if
the loop keeps on open for a period of time, DI will keep on triggering in that time interval.
z
NO (normal open): The signal loop is open under normal conditions. When the loop
becomes closed, DI will be triggered until the loop becomes open again. In other words, if
the loop keeps on closed for a period of time, DI will keep on triggering in that time
interval.
(2)
Configuration of DO (Alarm Input) device
Click the tab of “DO” and it will show the menu of “DI” configuration. Each row represents
DO (Alarm Output) device. Click the “Status” column in any row and it will pop up the two
Status types for your selection.