Transport Cylinder Limit Switch (L5):
This switch is active from when the cylinders
are retracted (hopper raised), and will deactivate
once the hopper is lowered fully.
• In the same action, a cylinder will lift the
conveyor’s discharge.
• To lower the hopper switches L3 and L2, must
be activated.
Discharge Raise Limit Switch (L4):
This switch contacts a bracket, when the
cylinder is retracted completely.
• The discharge will be at it’s highest point.
Shuttle Centre Limit Switch (L1):
The switch (at the centre of the rear frame) will
contact the conveyor frame once it arrives at the
centre of the tender.
• To shuttle the frame to centre, switches L3,
and L4 must be activated, L5 is deactivated.
Note:
To swing, lift and lower the conveyor into
working position, switch #4 must be active.
Shuttle Passenger-Side Limit Switch (L2):
The switch must contact the frame as it arrives
at the corner of the tender.
• To return the conveyor frame to the passenger-
side for stowing, switches #1, and #3 must be
activated, #2 is deactivated.
Simple adjustments to the limit switches, will
allow the rear conveyor to move correctly without
restriction or damage to the tender itself.
Fig 23 - Rotation centre limit switch
Fig 24 - Rotation centre limit switch
Fig 25 - Rotation centre limit switch
Fig 26 - Rotation centre limit switch
Summary of Contents for CST-1550
Page 1: ...OPERATOR S MANUAL COMMERCIAL SEED TENDER CST 1550...
Page 4: ...This page intentionally left blank...
Page 8: ...Operator s Manual CST 1550 1 2 01 2019 This page intentionally left blank...
Page 22: ...Operator s Manual CST 1550 2 14 01 2019 This page intentionally left blank...
Page 42: ...Operator s Manual CST 1550 3 20 01 2019 This page intentionally left blank...
Page 54: ...Operator s Manual CST 1550 4 12 01 2019 This page intentionally left blank...
Page 59: ...Operator s Manual CST 1550 01 2019 6 3 This page intentionally left blank...