77
GB
Stand the stove on a floor plate which meets the requirements
laid down on page 76. Measure to make sure that the size of
the floor plate and the distance between the stove and the wall
are at least as great as specified in the diagrams below. Allow at
least 1.0 metre from the stove door to any combustible part of
the building structure or interior fittings.
Important!
When placing the stove in a corner close to combustible
wall materials or against a wall with a gap of only 305 mm
to combustible materials, an extra side window with a heat-
reflecting surface must always be fitted.
365
100
250
450
*305
782
*637
Air inlet Ø64
Combustible wall
* Only permissible with extra side window. Please see page 96.
370
1190
360
1050
407
40
520
560
265
340
ca 1790
940
ca 1610
Air inlet Ø64
Combustible roof
Medium high model 2050
349
432
282
50
50
845
Air inlet Ø64
Fire-retardant wall of
brick or concrete
292
292
664
340
1050
1600
Air inlet Ø64
Tall model 2415
Min. 2100 to ceiling
*100
539
622
240
240
*399
*482
*100
1035
*895
Air inlet Ø64
Combustible wall
Installation distances to walls and ceiling
50
105
50
200
382
Air inlet Ø64
Fire-retardant wall of
brick or concrete
Fire-retardant wall of brick
or concrete
Fire-retardant wall of brick
or concrete