85
GB
Slide the connecting flue over the collar.
Make sure that the seal round the collar is
not dislodged.
Cut away the inner and outer marked
cover on the rear panel of the stove body.
LEK
Brytlock
LEK
Täcklock
LEK
LEK
Gäller ej!
Use sealing rope for a safe seal between the flue sleeve and the
connecting flue. If further sealing material is required, heat-
resistant sealant may be used.
LEK
The stove is supplied ready for connection
to a top flue. For rear-flue connections the
covering cap and collar need to exchange
places.
Loosen the top adjusting nuts for the support structure.
Adjust the support structure to ensure that it is perfectly
horizontal.
Leave the top adjusting nuts loose in order to make any
necessary adjustments to the height when installing the
soapstone blocks.
LEK
Mark out the centre of the hole to be made in the wall for a rear
flue connection. Make a hole at least 180 mm in diameter and
then secure the flue sleeve in the wall using heat-proof mortar
(not supplied).
Check the height to make sure that the hole aligns with the
chimney connection on the rear of the stove. Leave the mortar
to dry before connecting the stove to the flue.
Low model, flue height 940 mm
Covering cap
for flue
Partly punched cover
Rear flue connection to masonry chimney