PoolWarden Manual www.poolwardentraining.com 530-205-4520 31
Readings Screen”. Langelier is enabled after manual measurements have been entered in the “Handy
Menu”.
⧫
TrueDPD Menu:
If the optional TrueDPD PPM sensor is connected then use this menu to set up how it
operates.
⧫
Service QuickJmp
: When set to ON, pressing the
Left Arrow
from the ‘Default Readings Screen” will
jump to the “Service“ menu without requiring a password even if security is enabled. Pressing
Back
will
return to the “Default Readings Screen” and not the “Main Menu”. Press 2 or 3 to access the setpoint and
mixing time entery for ORP and pH. Pressing 2 or 3 are password protected.
⧫
Display Type: VFD:
Press
Enter
to cycle between VFD and LCD. The default display is the LCD type.
Clear / Reset Menu
Clear/Reset Menu
This Month On Times
Last Month On Times
All Calibrations
Energy Management
Flow Totalizers
Reset Everything
⧫
All Calibrations
: Clear all calibrations including pH, ORP and temperature, select “All Calibrations”
and press
Enter
to clear.
⧫
Energy Management: To reset to factory defaults all energy management settings within the
“Advanced” Menu select “Energy Management” and press
Enter
to clear. More will be covered on
Energy Management in the Advanced Menu section of this manual.
⧫
Flow Totalizers
: To clear the volume readings in the Flow Menu if a Digital Flow meter is installed
select “Flow Totalizers” and press
Enter
to clear.
⧫
Reset Everything
: To Reset all settings back to factory defaults. This clears all calibrations and sets
the relays back to the default control types. When selected, a Warning screen will display and you must
press
9
to proceed or any other button to exit without resetting everything.
⧫
Overlay Color:
White or Blue. The numbers and arrows work the same for both, the letters and symbols
below the numbers are different for both overlays.
⧫
Scroll Readings:
OFF or ON. When set to ON, when the PoolWarden goes to the default reading screen it
will instead scroll through the last 7 noontime readings at a 5 second interval for each day. If the health
department is doing an inspection and the data hasn’t been transferred to the log the readings can be
viewed on the PoolWarden without needing to touch a button.
Advanced Menu (Energy & CYA Management)
This menu includes items that are not required for the normal operation of PoolWarden and are considered
advanced features.
⧫
Time Profile 1 and 2:
The Time Profiles section of the Advanced menu works in conjunction with setting
up one of the Auxiliary Relays in the Relay Control Type menu to “Heater” and then creating Temperature
TrueDPD PPM: Pool1 - Select if Pool1, Pool2, Both or none.
⧫
TrueDPD Cycle:
The is the cycle time between measurements and
can be set to 5, 10, 15, 30 and 60 minutes.
⧫
Reagent: Liquid/Powder
- The TrueDPD supports two different
reagents for making the measurement. The standard powder mix is
low cost, accurate but darkens over time at higher temperatures.
The Liquid DPD that is made from Lamotte doesn’t require mixing
with water and doesn’t darken over time.
TrueDPD Menu
TrueDPD PPM: Pool1
TrueDPD Cycle: 5 min
Reagent: Liquid
Skip A Cycle:None
⧫
Clear/Reset Menu:
To clear all calibrations, reset everything to factory
defaults or to reset the monthly timers. This menu is available as the last
selection in the System Menu.
⧫
This Month On Times
: PoolWarden keeps track of the total “ON” times
for each relay for a running two month period. To clear the total “ON”
times for the current month select “This Month On Times” and press
Enter
to clear
Last Month On Times
: PoolWarden keeps track of the total “ON” times
for each relay for a running two month period. To clear the total “ON”
times for last month select “Last Month On Times” and press
Enter.