PoolWarden Manual www.poolwardentraining.com 530-205-4520 24
Switch Input 3 or 4 (Default is 3). To turn the alarm status on if no flow is detected for Pool1 simply hit
the Enter Key to change the value from “none” to 1 (Flow Switch Input 1) and hit the Back key to save.
To turn the alarm status on if no flow is detected for Pool2 simply hit the Enter Key 3 times to change the
value from “none” to 3 (Flow Switch Input 3) and hit the Back key to save.
⧫
On If Overfeed - YES:
The factory default setting is “YES”. The alarm will turn on if this condition is
satisfied. To change the condition simply hit the Enter Key to change to NO and hit the Back Key to
save.
⧫
Off If Flow Off - none:
The factory default setting is “none” or disabled. The PoolWarden will not send
alarm notification if no flow is detected. Please Remember: Pool1 uses Flow Switch Input 1 or 2
(Default is 1) and Pool2 uses Flow Switch Input 3 or 4 (Default is 3). To turn the alarm status on if no
flow is detected for Pool1 simply hit the Enter Key to change the value from “none” to 1 (Flow Switch
Input 1) and hit the Back key to save. To turn the alarm status on if no flow is detected for Pool2 simply
hit the Enter Key 3 times to change the value from “none” to 3 (Flow Switch Input 3) and hit the Back key
to save.
⧫
On Delay 00:10:00:
The factory default setting is 10 Minutes. The alarm will only turn on if this
condition is satisfied for at least 10 Minutes. This command prevents multiple alarms if the sensor
reading is fluctuating back and forth. To change the command simply hit the Enter Key to enter a new
value and hit the Enter Key again to save or enter “0” zero to disable.
⧫
Off If Time < 00:00:00:
This is a time of day command. The factory default setting is “0” zero or
disabled. All alarm conditions will be OFF for the entire time of day until the time of day condition is met.
If not 00:00:00, the alarm will be off from midnight until the time in this command.
⧫
Off If Time > 00:00:00:
This is a time of day command. The factory default setting is “00:00:00” or
disabled. If not 00:00:00, the alarm will be OFF for the indicated time until midnight.
Alarm control types:
❑
Standard
: This is listed above and uses ORP values to set the alarm. Use this control type for the
alarms if ORP Calibration is enabled in the “System Menu”.
❑
ORP %:
When the ORP Calibration is disabled the sanitizer levels are changed by changing the ORP
setpoint. If the ORP setpoint is changed then the alarm values for ORP may also need to be changed
to reflect this. Using the ORP % for the alarm control type uses a percentage of the setpoint rather
than specific values so if the ORP setpoint is changed that is automatically reflected in the ORP part
of the alarms. The default value is 10%, if the ORP setpoint is 700, then the alarm values would be
630 and 770 mv.