PoolWarden Manual www.poolwardentraining.com 530-205-4520 18
Service
Relay Manual
Calibration P1
Calibration P2
Disable Relays
Clear Overfeed
TrueDPD PPM
Manual
ORP pH Tf Flow
681 7.7 75 ON a
695 7.5 102 ON
RlyP1
↑↓o_
P2_
↓o_
Default Readings Screen
Press
Back Key
GETTING STARTED
PROGRAMMING
Back
Relays
PH1 Acid(pH-)
ORP1 Feeded(ORP+)
Aux1 Not Used
Aux2 Not Used
Alarm1 Standard
PH2 Acid(pH-)
ORP2 Liquid(ORP+)
Aux3 Not Used
Aux4 Not Used
Alarm2 Standard
Security Setup
0 Admin
1 Tech
2 Tech
3-9 Service
Relay Type
Pool-1
Update Pool1
Pool-2
Update Pool2
PROGRAMMING - GETTING STARTED
The menu tree below represents the “Getting Started” menus that are necessary to get PoolWarden setup.
The remaining menus represent more advanced features that will be covered in later sections. Become very
familiar with the 4 menus below surrounding the Main Menu as they will be utilized most of the time. Any
menu utilizing the
Back
button for access can be password protected.
Step 1 - System Menu
The first step is to set the Date, Time and Day of the Week in the System Menu. Press the
Back
button to
access the “Main Menu” and scroll down to the “System Menu” and set the correct Date, Time and Day of the
week and then proceed to Step 2 below. Much more will be covered on the “System Menu” in the Advanced
section of this manual.
Step 2 - Security Setup Menu
The next step is to set up and assign passwords to the various personnel who will be working with or servicing
PoolWarden. Menus that are accessed from the “Default Readings Screen” using the
Back
button can be
password protected. The Handy Menu, Flow Menu and Alarm Menu are not Password Protected - anyone
can access them. From the “Default Readings Screen”, simply press the
Back
button to access the “Main
Menu” and use the
Down Arrow
to scroll to “Security Setup”. There are 3 levels of access that are defined
below. Scroll to the level and assign up to a 10 digit password (numbers only) and press “Enter” to save the
password. Entering zero “0” will disable a password and the maximum value for any password is
4294967295.
●
1 Admin Password:
Access to all menus within PoolWarden including ability to add, delete, or change
passwords. If the Admin Password has been lost, please read the troubleshooting section at the end of
this manual.
●
2 Technician Passwords:
Access only to the Service Menu, Data Recording Menu, Relay Setup and
Advanced Menus.
●
7 Service Passwords:
Access only to the Service and Data Recording Menus.
If direct communication is required with the optional PW-LAN, security must be enabled to allow access to the
Main Menu.
m
v
Service LAN
Data Security
Relays Relay Type
Advanced System
Main Menu