Commander SE User Guide
Issue Number 5
43
Parameter 5 Set to PAd
Keypad control
Figure 6.7 Keypad connections
Used to start the Drive.
Used to stop the Drive. Also used to reset the Drive after a trip.
After a reset command, the Drive will need a start command to run.
Used to reverse the direction of rotation of the motor
(when parameter 26 = On).
Enter the motor current rating (taken from the motor name plate).
The Drive rated current value is the 100% RMS output current value of the Drive. This
value can set to a lower value but not a higher value.
Enter the rated full load speed of the motor (taken from the motor name plate).
The rated speed is used to calculate the correct slip for the motor.
The rated speed is the synchronous speed - the 100% full load slip of the motor.
Example: For a 4 pole motor with a synchronous speed of 1500rpm and a slip speed
of 70rpm, enter 1430rpm in parameter 07.
A value of zero entered into parameter 07 means slip compensation is
disabled.
If the full load speed of the motor is above 9999rpm, enter a value of 0 in
parameter 07. This will disable slip compensation as values greater than 9999
cannot be entered into this parameter.
Enter the motor rated voltage (taken from the motor name plate).
The motor power factor cos
ϕ
(taken from the motor name plate).
No.
Function
Type
Limitations
Range
Units
Defaults
06
Motor
rated
current
RW
U
0 - Drive rated
current
A
Drive rating
EUR
Drive rating
USA
No.
Function
Type
Limitations
Range
Units
Defaults
07
Motor
rated
speed
RW
U
0 - 9999
rpm
1500
EUR
1800
USA
NOTE
NOTE
No.
Function
Type
Limitations
Range
Units
Defaults
08
Motor
rated
voltage
RW
U
0 - 240
0 - 480
V
230/400
EUR
230/460
USA
No.
Function
Type
Limitations
Range
Units
Defaults
09
Motor power
factor
RW
U
0 - 1.00
0.85
EUR
0.85
USA