INSTALLER:  LEAVE THIS MANUAL WITH THE APPLIANCE.

CONSUMER:  RETAIN THIS MANUAL FOR FUTURE REFERENCE.

NEVER LEAVE CHILDREN OR OTHER AT RISK INDIVIDUALS ALONE WITH THE APPLIANCE.

INSTALLATION AND 

OPERATING INSTRUCTIONS

Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 

103 Miller Drive, Crittenden, Kentucky, USA, 41030

Phone (705)721-1212 • Fax (705)722-6031 • www.continental

fi

 replaces.com • ask@continental

fi

 re.on.ca

1.31B

$10.00

CERTIFIED FOR CANADA AND UNITED STATES USING ANSI/CSA METHODS.

SAFETY INFORMATION

!

WARNING

- Do not store or use gasoline or other fl ammable 
vapors and liquids in the vicinity of this or any 
other appliance.
- WHAT TO DO IF YOU SMELL GAS:
• 

Do not try to light any appliance.

• 

Do not touch any electrical switch; do not use        
any phone in your building.

• 

Immediately call your gas supplier from a        
neighbour’s phone.  Follow the gas supplier’s        
instructions.

• 

If you cannot reach your gas supplier, call the        
fi re department.

- Installation and service must be performed by a 
qualifi ed installer, service agency or the supplier.

If the information in these instructions 
are not followed exactly, a fi re or 
explosion may result causing property 
damage, personal injury or loss of life.

HOT GLASS 

WILL CAUSE 

BURNS

.

DO NOT TOUCH 

GLASS UNTIL 

COOLED

.

NEVER 

ALLOW CHILDREN TO 

TOUCH GLASS

.

!

DANGER

A barrier designed to reduce the risk of burns from 
the hot viewing glass is provided with this appliance 
and shall be installed for the protection of children 
and other at-risk individuals.

This appliance may be installed in an aftermarket, 
permanently located, manufactured home (USA 
only) or mobile home, where not prohibited by 
local codes.

This appliance is only for use with the type of gas  
indicated on the rating plate. This appliance is 
not convertible for use with other gases, unless a 
certifi ed kit is used.

CONFORMS TO AMERICAN NATIONAL STANDARDS: ANSI Z21.50, CERTIFIED TO CANADIAN CSA 2.22 FOR VENTED GAS FIREPLACES.

SAFETY

 BARRIER

BCDV36CFNTR & 

BCDV36CFNTRE

NATURAL GAS MODEL

BCDV36CFPTR & 

BCDV36CFPTRE

PROPANE GAS MODEL

Summary of Contents for BCDV36CFNTR

Page 1: ...gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the supplier If the information in these instructions are not followed exact...

Page 2: ...TION 29 5 3 2 EXTENDED HORIZONTAL AND CORNER TERMINAL INSTALLATION 29 5 3 3 VERTICAL AIR TERMINAL INSTALLATION 30 5 4 VERTICAL THROUGH EXISTING CHIMNEY 31 5 5 GAS INSTALLATION 32 5 6 MOBILE HOME INSTA...

Page 3: ...ENCLOSURE CLEARANCES Side Wall See the section INSTALLATION FRAMING See the section VENTING and INSTALLATION See the section FRAMING See the sections MINIMUM ENCLOSURE CLEARANCES for drywall or other...

Page 4: ...no circumstances should this appliance be modified This appliance must not be connected to a chimney flue pipe serving a separate solid fuel burning appliance Do not use this appliance if any part ha...

Page 5: ...5 W415 1516 A 10 22 15 EN 2 1 DIMENSIONS 34 864mm 381 2 978mm 241 4 616mm 8 203mm 3 76 2mm GASINLET 5 127mm 17 432mm 15 381mm 40 1016mm 27 686mm 4 102mm 7 178mm SAFETY BARRIER...

Page 6: ...ould choose a location where the vent will pass through the house without cutting a floor or roof joist If the appliance is installed directly on carpeting vinyl tile or other combustible material oth...

Page 7: ...on noises during heating up and cooling down cycles are normal and are to be expected Use only accessories designed for and listed with your specific appliance A barrier designed to reduce the risk of...

Page 8: ...VENT SUPERIEUR 2 BACK ARRIERE 0 VENT BOTTOM EVENT INFERIEUR 1 MANTEL MANTEAU 12 MAXIMUM HORIZONTAL EXTENSION L EXTENSION HORIZONTALE MAXIMALE 2 SEE INSTRUCTION MANUAL FOR GREATER EXTENSIONS REFERER AU...

Page 9: ...nt pipe shield or attic insulation shield when penetrating interior walls floor or ceiling NOTE If for any reason the vent air intake system is disassembled reinstall per the instructions provided for...

Page 10: ...exible components with the following termination kits wall terminal kit GD222 GD222R or 1 12 to 7 12 pitch roof terminal kit GD110 8 12 to 12 12 roof terminal kit GD111 flat roof terminal kit GD112 or...

Page 11: ...W415 1516 A 10 22 15 EN 3 2 TYPICAL VENT INSTALLATION 16 406MM MINIMUM 16 406MM MINIMUM 40 FT 12M MAXIMUM 3 FT 1M MINIMUM 40 FT 12M MAXIMUM 3 FT 1M MINIMUM TOP VENT REAR VENT 24 1 4 616MM MIN 33 838M...

Page 12: ...12 W415 1516 A 10 22 15 EN 20 508MM MAXIMUM 24 1 4 616MM MINIMUM PLUS RISE 10 254MM MINIMUM 32 3 8 822MM BCDV36 42 3 8 1076MM MINIMUM PLUS RISE 24 610MM MAXIMUM See VENTING section...

Page 13: ...orizontal run in addition to 45 offset In this case 0 rise is acceptable when using rigid Flexible venting must maintain a 6 152mm rise See illustration below Use the periscope kit to locate the air t...

Page 14: ...06mm 16 406mm Clearance above the roof O 2 0 6m 2 0 6m Clearance from an adjacent wall including neighbouring buildings P 8 2 4m 8 2 4m Roof must be non combustible without openings Q 3 0 9m 3 0 9m Se...

Page 15: ...he vertical rise equal to or greater than the horizontal run 3 times the vertical rise equal to or greater than the horizontal run 13 4A REAR EXIT Horizontal Termination Vertical Termination Vertical...

Page 16: ...horizontal vent lengths Hr and offsets Ho in feet HR combined horizontal vent lengths in feet HO offset factor 03 total degrees of offset 90 in feet VT combined vertical vent lengths in feet 3 7 ELBO...

Page 17: ...90 5 4 FT 1 7m HT HR HO 4 5 FT 1 4m 5 4 FT 1 6m 9 9 FT 3m HT VT 9 9 FT 3m 11 FT 3 4m 20 9 FT 6 4m Formula 1 HT VT 9 9 FT 3m 11 FT 3 4m Formula 2 HT VT 40 FT 12 2m 20 9 FT 6 4m 40 FT 12 2m Since both...

Page 18: ...both formulas are met this vent configuration is acceptable The shaded area within the lines represents acceptable values for HT and VT 90 V1 H1 H2 90 Example V1 4 FT 1 2m V2 1 5 FT 0 5m VT V1 V2 4 F...

Page 19: ...within the lines represents acceptable values for HT and HT HT VT 16 3A For vent configurations requiring more than two 90 elbows the following formulas apply Formula 1 HT VT Formula 2 HT VT 40 feet...

Page 20: ...6 3_2B For vent configurations requiring more than two 90 elbows the following formulas apply Formula 1 HT 3 5VT Formula 2 HT VT 24 75 feet 7 5m Example V1 4 FT 1 2m V2 1 5 FT 0 5m VT V1 V2 4FT 1 2m 1...

Page 21: ...r vent configurations requiring one or more 90 elbows top exit or one or more 90 elbows rear exit the following formulas apply Formula 1 HT VT Formula 2 HT VT 40 feet 12 2m Example V1 5 FT 1 5m V2 6 F...

Page 22: ...rmulas apply Formula 1 HT 3 VT Formula 2 HT VT 40 feet 12 2m Example V1 2 FT 0 6m V2 1 FT 0 3m V3 1 5 FT 0 5m VT V1 V2 V3 2FT 0 6m 1FT 0 3m 1 5FT 0 5m 4 5 FT 1 4m H1 6 FT 1 8m H2 2 FT 0 6m HR H1 H2 6F...

Page 23: ...ket assembly to the rear and top of the appliance using 4 8 x inch Hex Head Wildrill screws supplied Do not overtighten The gasket needs only to be snug against the firebox Before attaching elbows to...

Page 24: ...EALANT W573 0002 NOT SUPPLIED OR BLACK HIGH TEMP MILL PAC W573 0007 NOT SUPPLIED WITH THE EXCEPTION OF THE APPLIANCE EXHAUST FLUE COLLAR WHICH MUST BE SEALED USING MILL PAC IF USING PIPE CLAMPS TO CON...

Page 25: ...the firestop assembly before proceeding to ensure the brackets on the rear surface fit to the inside surface of the horizontal framing The length of the vent shield may be cut shorter for combustible...

Page 26: ...ply a bead of caulking not supplied to the framework or to the Wolf Steel vent pipe shield plate or equivalent in the case of a finished ceiling and secure over the opening in the ceiling A firestop m...

Page 27: ...additional length needed for the finished wall surface Apply a heavy bead of the high temperature sealant W573 0007 Mill Pac not supplied to the inner sleeve of the air terminal Slip the vent pipe a...

Page 28: ...ng underneath the sides and upper edge of the shingles Ensure that the air terminal connector is properly centred within the flashing giving a 3 4 19mm margin all around Fasten to the roof Do not nail...

Page 29: ...ecure to the exterior wall and make weather tight by sealing with caulking not supplied The air terminal mounting plate may be recessed into the exterior wall or siding no greater than the depth of th...

Page 30: ...shingles above and to the sides of the air terminal connector Place the flashing over the air terminal connector and slide it underneath the sides and upper edge of the shingles Ensure that the air t...

Page 31: ...rectly off the appliance Follow vent manufacturer s installation instructions Different manufacturer s venting components must not be combined Once the preferred manufacturer s appliance adaptor has b...

Page 32: ...home appliance Conversion Kits This appliance is field convertible between Natural Gas NG and Propane LP To convert from one gas to another consult your Authorized dealer distributor 5 5 GAS INSTALLAT...

Page 33: ...TO MAINTAIN AIR SPACE CLEARANCE MAY CAUSE OVER HEATING AND FIRE PREVENT CONTACT WITH SAGGING OR LOOSE INSULATION OR FRAMING AND OTHER COMBUSTIBLE MATERIALS BLOCK OPENING INTO THE CHASE TO PREVENT ENT...

Page 34: ...4 438mm recessed depth Rear Exit 40 1 2 991mm to enclosure top from base of the appliance 54 1372mm to ceiling from base of the appliance Top Exit 49 1245mm to enclosure top from base of the applianc...

Page 35: ...FOR THE VENT IN THIS 14 356MM WIDE AREA CENTRED ALONG THE FRONT OF THE APPLIANCE NO COMBUSTIBLES ARE ALLOWED WARNING Combustion protrusions such as mantels and shelves may occur at or after a minimum...

Page 36: ...TO ALLOW FOR PROPER DOOR OPERATION 12 305MM TO COMBUSTIBLE MANTLE IMPORTANT Encroaching in this area with finishing material will interfere with the opening of the door 413 8 1050mm 4 0 1 2 1 0 2 8 m...

Page 37: ...losure space around and above the appliance must be left unobstructed See VENTING section 6 3 MINIMUM ENCLOSURE CLEARANCES 241 2 622mm MINIMUM PLUSRISE 401 2 1029mm 34 864mm 2 51mm 1 25mm 2 51mm 0 IFN...

Page 38: ...1mm 0 IFNON COMBUSTIBLE FINISHINGIS USEDSUCHAS BRICKANDSTONE STEELHEADER REQUIRED 34 864mm 61 2 165mm MINNON COMBUSTIBLE MATERIAL 11 2 38mm 6 3 2 TOP VENT ENCLOSURE TOP EXIT ENCLOSURE The appliance re...

Page 39: ...m UNIT CLEARANCE SURROUNDKIT OPTIONALCONVEXFRONT 61 2 165mm MIN 373 8 949mm 33 8 85mm 33 8 85mm FINISHEDFLOOR FIREPLACE RISER STANDOFF STEEL HEADER SUPPLIED FIREPLACE RISER 33 8 85mm STANDOFF STEEL HE...

Page 40: ...BLE FACING MATERIAL FINISH MATERIAL 2 51mm 4 102mm 6 152mm 4 102mm 2 51mm 0 0mm 6 4 NON COMBUSTIBLE FACING MATERIAL APPLIANCE RECESS OR ALCOVE AREA NOTE Recesses or alcoves above the appliance can be...

Page 41: ...LOURATION 73 1 6 6 MINIMUM MANTEL CLEARANCES Position the remote receiver in the valve compartment close to the electrical junction box Ensure the receiver is on top of the placement label if equipped...

Page 42: ...ALS MUST NOT INTERFERE WITH AIR FLOW THROUGH AIR OPENINGS LOUVRES OPENINGS OPERATION OF LOUVRES OR DOORS OR ACCESS FOR SERVICE OBSERVE ALL CLEARANCES WHEN APPLYING COMBUSTIBLE MATERIALS BEFORE DOOR IS...

Page 43: ...colours may vary During the initial use of the appliance the colours will become more uniform as colour pigments burn in during the heat activated curing process A Place the back log 1 onto the log su...

Page 44: ...icated 12 7mm LOGO 12 7mm ROCK SUPPORT BRACKET LOG SUPPORT BRACKET WARNING RAK ROCK ADAPTOR KIT IS NECESSARY WITH THIS KIT REAL ROCKS MUST NOT BE USED IN THIS APPLIANCE HEAT WILL CAUSE THEM TO EXPLODE...

Page 45: ...k washer and wing nut provided Ensure that the blower does not touch the appliance base or the firebox Attach the connectors from the black and white wires to the thermal switch and secure the thermal...

Page 46: ...cally start approximately 10 minutes after lighting the appliance and will run for approximately 30 45 minutes after the appliance has been turned off Use of the fan increases the output of heat Drywa...

Page 47: ...ny electric switch do not use any phone in your building 1 Stop Read the above safety information on this label 2 Turn remote wall switch to off position 3 Turn off all electrical power to the applian...

Page 48: ...the pilot burner to be lit until the thermo couple has cooled Allow approximately 60 seconds for the thermocouple to cool When lighting and re lighting the gas knob cannot be turned from pilot to off...

Page 49: ...can be checked by turning screw A counter clockwise until loosened and then placing pressure gauge tubing over the test point Gauge should read 7 178mm minimum 4 5 114mm water column for natural gas o...

Page 50: ...urning Clean out any of the ports which may not be burning or are not burning properly D Check to see that the pilot flame is large enough to engulf the flame sensor and or thermocouple thermopile as...

Page 51: ...ection of the burner media and firebox Refer to the door removal section and remove the door as instructed Carefully remove media if necessary logs glass brick panels etc Using a vacuum with a soft br...

Page 52: ...on with a recommended fireplace glass cleaner Thereafter clean as required If the glass is not kept clean permanent discoloration and or blemishes may result HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GL...

Page 53: ...ive the following information Model Serial Number of appliance Installation date of appliance Part number Description of part Finish IDENTIFIES ITEMS WHICH ARE NOT ILLUSTRATED FOR FURTHER INFORMATION...

Page 54: ...010 1340 DOOR ASSEMBLY W667 0018 GASKET TAPE X4 YES W562 0062 DOOR GASKET 9 14 13 12 11 W010 0538 7 FLUE CAP c w GASKET W290 0039 7 FLUE CAP GASKET YES YES W290 0184 GASKET FLUE PIPE ASSY 4 EXHAUST FL...

Page 55: ...14 15 14 16 14 17 14 14 14 21 14 20 14 14 19 14 18 18 20 17 16 15 19 23 22 21 14 20 YES YES W725 0046 SHUT OFF VALVE W660 0009 ON OFF SWITCH YES YES YES W725 0026 VALVE LP W725 0025 VALVE NG W010 079...

Page 56: ...MS MAY NOT APPEAR EXACTLY AS ILLUSTRATED 14 15 14 16 14 17 14 19 14 20 14 14 14 23 14 22 14 22 14 14 21 14 18 25 24 23 YES YES W725 0046 SHUT OFF VALVE W660 0009 ON OFF SWITCH YES YES YES W725 0049 VA...

Page 57: ...40 41 S36CVP 31 32 33 CFT36CV W690 0002 THERMODISC F45 F60 HANDHELD REMOTE CONTROL YES YES W135 0186 LEFT CROSSOVER LOG W135 0183 REAR LOG W135 0188 RIGHT CROSSOVER LOG W135 0184 LEFT MIDDLE LOG W135...

Page 58: ...valve Faulty valve Replace Pilot burning no gas to main burner gas knob is on HI wall switch thermostat is on Thermostat or switch is defective Connect a jumper wire across the wall switch terminals...

Page 59: ...Gauge should read as described on the chart below Check that main burner is operating on HI AFTER TAKING PRESSURE READINGS BE SURE TO TURN SCREWS CLOCKWISE FIRMLY TO RESEAL DO NOT OVER TORQUE Leak te...

Page 60: ...nfigurations insufficient makeup air or negative air pressures which may or may not be caused by mechanical systems such as exhaust fans furnaces clothes dryers etc Any damages to appliance combustion...

Page 61: ...61 W415 1516 A 10 22 15 EN 20 0 SERVICE HISTORY...

Page 62: ...62 W415 1516 A 10 22 15 EN 44 1 21 0 NOTES...

Page 63: ...63 W415 1516 A 10 22 15 EN 44 1...

Page 64: ......

Page 65: ...roximit de cet ap pareil ou tout autre appareil QUE FAIRE SI VOUS D TECTEZ UNE ODEUR DE GAZ N allumez aucun appareil Ne touchez aucun interrupteur lectrique n utilisez aucun t l phone dans votre immeu...

Page 66: ...93 5 3 3 INSTALLATION DE LA TERMINAISON HORIZONTALE PROLONG E AJUSTABLE 94 5 3 4 INSTALLATION DE LA TERMINAISON VERTICALE 95 5 4 TERMINAISON VERTICALE TRAVERS UNE CHEMIN E EXISTANTE 96 5 5 INSTALLATI...

Page 67: ...MAUX DE L ENCEINTE pour les cloisons s ches ou autre mat riau combustible Voir la section D GAGEMENTS MINIMAUX DE LA TABLETTE Voir la section OSSATURE Mur lat ral Voir la section OSSATURE Voir les sec...

Page 68: ...tretien Un entretien plus fr quent pourrait tre n cessaire en raison des peluches provenant des tapis literie etc L emplacement de l appareil doit tre gard libre de tous mat riaux combustibles essence...

Page 69: ...69 W415 1516 A 10 22 15 FR ENTR E DUGAZ 34 864mm 381 2 978mm 241 4 616mm 8 203mm 3 76mm 5 127mm 17 432mm 15 381mm 40 1016mm 27 686mm 4 102mm 7 178mm L CRAN DE PROTECTION 2 1 DIMENSIONS...

Page 70: ...her ou de toit Si l appareil est install directement sur un tapis sur une surface de vinyle ou tout autre rev tement de plancher combustible autre que le bois l appareil devra tre mont sur un panneau...

Page 71: ...r lorsque le gaz circule 3 5 9mb de colonne d eau 10 25mb de colonne d eau Cet appareil est approuv pour installation dans les salles de bain les chambres coucher ou les chambres studio et convient po...

Page 72: ...385 1974 NOT FOR USE WITH SOLID FUEL FOR USE WITH GLASS DOORS CERTIFIED WITH THIS UNIT ONLY WARNING THIS FIREPLACE USES AND REQUIRES A FAST ACTING THERMOCOUPLE REPLACE ONLY WITH A FAST ACTING THERMOCO...

Page 73: ...s murs int rieurs le plancher ou le plafond sont travers s NOTE Si pour une raison quelconque le syst me d vents de prise d air est d mont r installez le selon les instructions fournies dans l install...

Page 74: ...lat GD112 ou l ensemble p riscopique GD201 pour p n tration des murs sous le niveau du sol Lorsque vous utilisez des conduits flexibles conjointement avec les diff rentes terminaisons utilisez l ensem...

Page 75: ...22 15 FR 3 2 INSTALLATIONS TYPIQUES D VENTS 16 406MM MINIMUM 16 406MM MINIMUM 40 PI 12M MAXIMUM 3 PI 1M MINIMUM 40 PI 12M MAXIMUM 3 PI 1M MINIMUM VACUATION SUR LE DESSUS VACUATION L ARRI RE 24 1 4 61...

Page 76: ...76 W415 1516 A 10 22 15 FR BCDV36 42 3 8 1076MM MINIMUM PLUS LA PENTE Voir la section VACUATION 10 254MM MINIMUM 32 3 8 822MM 24 610MM MAXIMUM 24 1 4 616MM MINIMUM PLUS LA PENTE 20 508MM MAXIMUM...

Page 77: ...0 508mm MAXIMUM 6 152mm MINIMUM D L VATION 3 3 INSTALLATIONS PARTICULI RES D VENTS 3 3 1 ENSEMBLE P RISCOPIQUE 12 305MM MINIMUM AU NIVEAU DU SOL 12 305MM MINIMUM AU NIVEAU DU SOL 30 762MM MINIMUM 30 7...

Page 78: ...ombustible et sans ouvertures Q 3 0 9m 3 0 9m Voir le tableau pour les dimensions d un mur plus large R 6 1 8m 6 1 8m Voir le tableau pour les dimensions d un mur plus profond La terminaison ne doit p...

Page 79: ...de ou gale la course horizontale VACUATION SUR LE DESSUS 13 2A VACUATION L ARRI RE Terminaison horizontale Terminaison verticale La course verticale est plus grande ou gale la course horizontale La co...

Page 80: ...zontales combin es en pieds HO facteur de la valeur d une d viation 0 03 du total des degr s de d viation 90 en pieds VT longueur des courses verticales combin es en pieds 15 1A PIEDS POUCES MILLIM TR...

Page 81: ...iquent Formule 1 HT VT Formule 2 HT VT 40 pieds 12 2m Exemple V1 3 PI 0 9m V2 8 PI 2 4m VT V1 V2 3PI 0 9m 8PI 2 4m 11PI 3 4m H1 2 5 PI 0 8m H2 2 PI 0 6m HR H1 H2 2 5PI 0 8m 2PI 0 6m 4 5 PI 1 4m HO 0 0...

Page 82: ...rmules sont respect es cette configuration d vacuation est acceptable La section ombrag e l int rieur des lignes repr sente des valeurs acceptables pour HT et VT 90 V1 H1 H2 90 Exemple V1 4 PI 1 2m V2...

Page 83: ...r HT et VT HT VT 16 3A Lorsque la configuration de l vacuation exige plus qu un coude de 90 les formules suivantess appliquent Formule 1 HT VT Formule 2 HT VT 40 pieds 12 2m Exemple V1 9 PI 2 7m V2 6...

Page 84: ...que la configuration de l vacuation exige plus qu un coude de 90 les formules suivantes s appliquent Formule 1 HT 3 5VT Formule 2 HT VT 24 75 pieds 7 5m Exemple V1 4 PI 1 2m V2 1 5 PI 0 5m VT V1 V2 4P...

Page 85: ...mules suivantes s appliquent Formule 1 HT VT Formule 2 HT VT 40 pieds 12 2m Exemple V1 5 PI 1 5m V2 6 PI 1 8m V3 10 PI 3 1m VT V1 V2 V3 5PI 1 5m 6PI 1 8m 10PI 3 1m 21PI 6 4m H1 8 PI 2 4m H2 2 5 PI 0 8...

Page 86: ...pliquent Formule 1 HT 3 VT Formule 2 HT VT 40 pieds 12 2m Exemple V1 2 PI 0 6m V2 1 PI 0 3m V3 1 5 PI 0 5m VT V1 V2 V3 2PI 0 6m 1PI 0 3m 1 5PI 0 5m 4 5PI 1 4m H1 6 PI 1 8m H2 2 PI 0 6m HR H1 H2 6PI 1...

Page 87: ...llet de 4 102mm 4 0 PR PARATION AVANT L INSTALLATION AVERTISSEMENT IL EST ESSENTIEL QUE LE COUVERCLE D VACUATION SOIT INSTALL SINON L APPAREIL NE FONCTIONNERA PAS CORRECTEMENT ET POURRAIT CAUSER DES B...

Page 88: ...PAS NE SERREZ PAS LA GAINE FLEXIBLE RISQUE D INCENDIE D EXPLOSION OU D ASPHYXIE SI L ENSEMBLE DU SYST ME DE CONDUIT D VENT N EST PAS AD QUATEMENT SOUTENU IL RISQUE DE FL CHIR OU DE SE S PARER UTILISEZ...

Page 89: ...la profondeur du mur combustible A Appliquez un joint de calfeutrage non fourni tout autour de la bordure de la face int rieure de l espaceur coupe feu installez l espaceur coupe feu contre le trou e...

Page 90: ...aux combustibles Une fois que le conduit d vacuation est en place appliquez un agent d tanch it entre le conduit d vacuation et l espaceur coupe feu C Dans le grenier faites glisser le collet de condu...

Page 91: ...vis 8 Scellez avec du scellant haute temp rature W573 0002 non fourni C Ins rez les gaines dans le coupe feu tout en conservant le d gagement n cessaire aux mat riaux combustibles En soutenant la term...

Page 92: ...teur de terminaison visible au dessus du haut du solin Glissez le solin sous les c t s et le bord sup rieur des bardeaux Assurez vous que le connecteur de terminaison est bien centr dans le solin en l...

Page 93: ...nt compte de la longueur additionnelle n cessaire pour la surface du mur fini et tout chevauchement de 1 31 8mm entre les composants d vacuation B Appliquez du scellant haute temp rature W573 0007 non...

Page 94: ...nduits int rieurs et les coudes aient suffisamment d espaceurs et que chaque composant est scell et fix solidement celui qui le pr c de Fixez le manchon t lescopique la course de l vent Fixez solideme...

Page 95: ...e flashing over the air terminal connector and slide it underneath the sides and upper edge of the shingles Ensure that the air terminal connector is properly centered within the flashing giving a 3 4...

Page 96: ...du fabricant du syst me d vacuation Des composants d vacuation de diff rents fabricants ne doivent pas tre combin s Une fois que l adaptateur de votre choix est install le reste du syst me d vacuatio...

Page 97: ...e installation dans une maison mobile l appareil doit tre fix au plancher Fixez l aide de vis 10 t te hexagonale ins r es dans les trous de la base teignez toujours la veilleuse et l alimentation en g...

Page 98: ...ersion pour le Canada ou le National Fuel Gas Code ANSI Z223 1 NFPA 54 pour les tats Unis D Lorsque vous manipulez des conduites de gaz soutenez la soupape de gaz pour viter que les con duites ne se p...

Page 99: ...E FAITS ENTI REMENT DE MAT RIAUX NON COMBUSTIBLES LES MAT RIAUX FAITS ENTI REMENT D ACIER DE FER DE BRIQUE DE TUILE DE B TON D ARDOISE DE VERRE OU DE PL TRE OU D UNE COMBINAISON DE CES MAT RIAUX SONT...

Page 100: ...ir aucune surface peinte en noir du devant de l appareil Les mat riaux incombustibles briques pierres carreaux de c ramique peuvent empi ter sur la partie noire D gagements minimaux de l appareil aux...

Page 101: ...est requis Ceci peut tre consid r comme un mur lat ral sans restriction de longueur 6 1 1 DIMENSIONS MINIMALES DE L OSSATURE POUR DES APPLICATIONS AVEC VACUATION SUR LE DESSUS NE CONSTUISEZ RIEN DANS...

Page 102: ...D QUATE DE LA PORTE 12 305MM LA TABLETTE COMBUSTIBLE IMPORTANT Pour permettre l ouverture de la porte les mat riaux de fini tion ne doivent pas d border dans cet espace 413 8 1050mm 4 0 1 2 1 0 2 8 m...

Page 103: ...ntraintes de temp rature l espace l int rieur de l enceinte autour de l appareil et au dessus doit demeurer sans ob struction 6 2 MINIMUM ENCLOSURE CLEARANCES 241 2 622mm MINIMUM PLUSRISE 401 2 1029mm...

Page 104: ...einte autour de l appareil et au dessus doit demeurer sans obstruc tion MAT RIAU COMBUSTIBLE 2 51mm UNLINTEAU ENACIEREST REQUIS 1 25mm 2 51mm 2 51mm 0 SIUNMAT RIAUDE FINITIONINCOMBUSTIBLE ESTUTILIS TE...

Page 105: ...TDU CONTOUROFFERT DES RIE FA ADECONVEXEOPTIONNELLE 61 2 165mm MIN 373 8 949mm 33 8 85mm 33 8 85mm PLANCHERFINI BASE D L VATION ESPACEUR LINTEAUEN ACIER BASE D L VATION 33 8 85mm ESPACEUR LINTEAU ENACI...

Page 106: ...51mm 4 102mm 6 152mm 4 102mm 2 51mm 0 0mm 6 3 MAT RIAU DE FINITION INCOMBUSTIBLE APPAREIL ZONE ENCASTR E OU ALC VE NOTE Les zones encastr es ou les alc ves au dessus de l appareil peuvent tre aussi pr...

Page 107: ...COLORATION 73 1 35 25 PLACER LE T L COMMANDE SUR CETTE TIQUETTE BASE DU FOYER BO TE DE D RIVATION Positionner le t l commande aux compartiment du soupape pr s du boite de d rivation lectrique Assurez...

Page 108: ...T FROID AU TOUCHER LES PORTES SONT LOURDES ET FRAGILES MANIPULEZ AVEC SOIN 75 1 7 0 FINITION Ouvrez la porte en d verrouillant les loquets sup rieur et inf rieur situ s du c t droit de la porte NOTE C...

Page 109: ...tes pour obtenir le meilleur effet possible La couleur des b ches peut varier Lors de la premi re utilisation de l appareil les couleurs deviendront plus uniformes mesure que leurs pigments seront abs...

Page 110: ...lement lorsqu elles sont expos es une flamme directe cependant prenez bien garde de ne pas boucher les orifices du br leur Le blocage des orifices du br leur peut cr er une flamme irr guli re des d p...

Page 111: ...re Les pattes du panneau de porce laine arri re doivent tre pli es vers le haut pour tre galit avec le support de retenue pour roches C Mettez les deux amas de roches en place en alignant les tiges s...

Page 112: ...ts Unis Si l appareil n tait pas muni d une soufflerie auparavant acheminez un fil lectrique de 60 Hz deux brins et mis la terre jusqu la bo te de d rivation Le fil doit tre isol et ne doit pas tre te...

Page 113: ...automatique ment en marche environ 10 minutes apr s l allumage de l appareil et fonctionnera de 30 45 minutes environ apr s l arr t de l appareil L utilisation de la soufflerie accro t le d bit de ch...

Page 114: ...euble 1 ARR TEZ Lisez les consignes de s curit sur l tiquette de fonctionnement 2 Mettez l interrupteur mural la position OFF 3 Coupez l alimentation lectrique l appareil et enlevez les piles 4 Cet ap...

Page 115: ...se refroidir Durant l allumage et le r allumage le bouton de contr le du gaz ne peut tourner de PILOT OFF moins de l enfoncer l g rement 1 Arr tez Lisez les consignes de s curit ci dessus 2 Coupez l a...

Page 116: ...la veilleuse sur l lectrode et sur le capteur de flamme VEILLEUSE THERMOCOUPLE THERMOPILE P I P I L O T N O L O T HI L O F F O A B VIS DE LA VEILLEUSE L ouverture du volet d air a t pr r gl e en usine...

Page 117: ...s ad quatement D Assurez vous que la flamme de la veilleuse est assez puissante pour envelopper la sonde de flamme et ou le thermocouple thermopile et qu elle atteigne le br leur E Remettez en place l...

Page 118: ...vez aussi tout d p t se trouvant sur l assemblage de la veilleuse et aussi s il y a lieu sur la thermopile le thermocouple le capteur de flamme et l allumeur NOTE Vous devrez possiblement nettoyer le...

Page 119: ...RE DE PORTE A Placez le cadre de la porte avec la devanture vers le bas en prenant soin de ne pas gratigner la peinture B Centrez la vitre avec joint d tanch it dans le cadre avec le c t pais du joint...

Page 120: ...l appareil Date d installation de l appareil Num ro de la pi ce Description de la pi ce Fini IDENTIFIE LES ARTICLES QUI NE SONT PAS ILLUSTR S POUR PLUS D INFORMATION CONTACTEZ VOTRE D TAILLANT AUTORIS...

Page 121: ...5 6 7 11 12 13 9 8 POUR LES PI CES DE REMPLACEMENT VOIR L ASSEMBLAGE DE LA SOUPAPE CES ARTICLES PEUT DIFF RER DE CELLE ILLUSTR L CRAN DE PROTECTION L ASSEMBLAGE DU L AVANT CFF L ASSEMBLAGE DU L CRAN D...

Page 122: ...W725 0046 W660 0009 OUI OUI OUI W725 0026 W725 0025 W010 0798 23 W750 0112 OUI W100 0093 W432 0077 24 OUI OUI W550 0001 BRAISES DE CHARBON W361 0016 LES BRAISES LUISANTES 25 PLATEAU DE BR LEUR CES ART...

Page 123: ...W725 0046 W660 0009 OUI OUI OUI W725 0049 W725 0032 W010 2517 W750 0112 OUI W010 0800 W750 0250 OUI W190 0044 W432 0046 23 21 22 23 18 20 17 16 15 19 24 24 25 CES ARTICLES PEUT DIFF RER DE CELLE ILLUS...

Page 124: ...6CVP 31 32 33 CFT36CV W690 0002 THREMODISQUE F45 F60 T L COMMANDE MANUELLE OUI OUI W135 0380 B CHE CROIS GAUCHE W135 0378 B CHE ARRI RE W135 0379 B CHE CROIS DROITE W135 0381 B CHE DES DROITE W135 038...

Page 125: ...t HI l interrupteur mural thermostat est ON Le thermostat ou l interrupteur sont d fectueux Reliez un fil de d rivation entre les bornes de l interrupteur mural si le br leur principal s allume rempla...

Page 126: ...ur la diagramme ci dessous Assurez vous que le br leur prinicpal fonctionne HI APR S AVOIR PRIS LA LECTURE DES PRESSIONS ASSUREZ VOUS DE TOURNER FERMEMENT LA VIS VERS LA DROITE POUR SCELLER NE SERREZ...

Page 127: ...egative air pressures which may or may not be caused by mechanical systems such as exhaust fans furnaces clothes dryers etc Any damages to appliance combustion chamber heat exchanger brass trim or oth...

Page 128: ......

Reviews: