7
W415-1516 / A / 10.22.15
EN
66.4%
GD36
2.4 GENERAL
INFORMATION
When the appliance is installed at elevations above 4,500 ft (1371m),
and in the absence of speci
fi
c recommendations from the local
authority having jurisdiction, the certi
fi
ed high altitude input rating shall
be reduced at the rate of 4% for each additional 1,000 ft (305m).
This appliance is approved for bathroom, bedroom and bed-sitting
room installations and is suitable for mobile home installation.
No external electricity (110 volts or 24 volts) is required for the gas
system operation.
Expansion / contraction noises during heating up and cooling down
cycles are normal and are to be expected.
Use only accessories designed for and listed with your speci
fi
c appliance.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the
appliance and must be installed.
RATES AND EFFICIENCIES
NG
LP
Altitude (FT)
0-4,500
0-4500
Max. Input (BTU/HR)
17,000
17,000
Max. Output Steady State (BTU/HR)
10,900
10,900
Ef
fi
ciency (w/the fan on)
64%
64%
A.F.U.E. (Annual Fuel Utilization Ef
fi
ciency)
53%
53%
Min. Inlet Gas Supply Pressure
4.5" (11mb) w.c.
11" (27mb) w.c.
Max. Inlet Gas Supply Pressure
7" (17mb) w.c.
13" (32mb) w.c.
Manifold Pressure (Under Flow Conditions)
3.5" (9mb) w.c.
10" (25mb) w.c.
FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND
QUALITY!