39
W415-1516 / A / 10.22.15
EN
6.3.3 FINISHED FLOOR INSTALLATION
When installing to a
fi
nished
fl
oor the appliance riser must create a minimum clearance of 3 3/8" (85mm) from
the
fi
nished
fl
oor to the bottom of the appliance.
When installing to a hearth the appliance riser must create a minimum clearance of 3 3/8" (86mm) PLUS the
height of the hearth from the
fi
nished
fl
oor to the bottom of the appliance.
6.3.4 HEARTH INSTALLATION
CLEANFACE SURROUND
CLEARANCE
FINISHED FLOOR
CLEARANCE
3 3/8"
85mm
UNIT
CLEARANCE
SURROUND KIT
OPTIONAL CONVEX FRONT
6 1/2" 165mm MIN
37 3/8"
949mm
3 3/8"
85mm
3 3/8"
85mm
FINISHED FLOOR
FIREPLACE
RISER
STAND OFF
STEEL
HEADER
(SUPPLIED)
FIREPLACE
RISER
3 3/8"
85mm
STAND OFF
STEEL
HEADER
(SUPPLIED)
CEMENT BOARD
PANEL
(SUPPLIED)
COMBUSTIBLE
MATERIAL
SAFETY BARRIER
CLEANFACE SURROUND
FINISHED FLOOR
CLEARANCE
3 3/8"
85mm
UNIT
CLEARANCE
SURROUND KIT
FIREPLACE
RISER
3 3/8"
85mm
HEARTH
PLUS HEARTH
HEIGHT
3 3/8"
85mm
PLUS HEARTH
HEIGHT
HEARTH
CLEARANCE
3 3/8"
85mm
FINISHED FLOOR
FIREPLACE
RISER
6 1/2" 165mm MIN
CEMENT BOARD
PANEL
(SUPPLIED)
COMBUSTIBLE
MATERIAL
STAND OFF
STEEL
HEADER
(SUPPLIED)
STAND OFF
STEEL
HEADER
(SUPPLIED)
OPTIONAL CONVEX FRONT
37 3/8"
949mm
PLUS
HEARTH
HEIGHT
SAFETY BARRIER
Summary of Contents for BCDV36CFNTR