6.2 MINIMUM FRAMING DIMENSIONS
STEEL HEADER
REQUIRED (SUPPLIED)
49"
1245mm
(TOP EXIT)
(REAR EXIT)
40 1/2”
1029mm
1 1/2”
38mm
14”
356mm
17 1/4”
438mm
40 1/2"
1028mm
MAX
MIN
1 1/2”
38mm
MAX
38 3/4”
984mm
FOR TOP EXIT APPLICATIONS: DO NOT BUILD INTO THIS AREA. IT MUST BE LEFT CLEAR TO
PROVIDE ADEQUATE CLEARANCE FOR THE VENT. IN THIS 14" (356MM) WIDE AREA CENTRED
ALONG THE FRONT OF THE APPLIANCE, NO COMBUSTIBLES ARE ALLOWED.
!
WARNING
Combustion protrusions such as mantels and shelves may occur at or after a minimum distance of 2" (51mm)
away from the side of the appliance. Thereafter, the depth of any protrusions must be equal to or less than the
distance from the side of the appliance up to a depth of 6" (152mm), after which no greater clearance than 6"
(152mm) is required. This can be considered a side wall with no length boundary.