ÉCHANTILL
ON
CONFORMS TO / CONFORME AUX: ANSI Z21.50-2014, CERTIFIED TO / CERTIFIE CSA 2.22-2014 VENTED GAS FIREPLACE / FOYER À GAZ VENTILÉ.
SERIAL NUMBER/NO. DE SERIE:
BGD36CF
FOYER A GAZ VENTILE DIRECT. HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A COUCHER, UNE
SALLE DE BAIN ET UN STUDIO. APPROPRIE POUR INSTALLATION DANS UNE MAISON MOBILE SI SON
INSTALLATION CONFORME AUX EXIGENCES DE LA NORME CAN/CSA Z240MH SERIE DE MAISONS MOBILES
EQUIPEES AU GAZ, EN VIGUEUR AU CANADA OU AUX ETATS-UNIS DE LA NORME DE SECURITE ET DE
CONSTRUCTION DE MAISONS MANUFACTUREES, TITRE 24 CFR, SECTION 3280. DANS LE CAS OU CETTE
NORME D'ETATS-UNIS NE PEUT ETRE APPLIQUEE, SE REFERER A LA NORME RELATIVE AU CRITERE DE
MESURES DE SECURITE CONTRE L'INCENDIE POUR LES INSTALLATIONS DANS LES MAISONS
MANUFACTURES, LES SITES ET LES COMMUNAUTES, ANSI/NFPA 501A. LORSQU'IL EST INSTALLE AVEC LA
TROUSSE POUR ECRAN GD-565KT, LE FOYER EST CONFORME A LA NORME DE CERTIFICATION DE L'ACG
CR95-006.
POUR UNE UTILISER SEULMENT AVEC BARRIÈRE W565-0178. SUIVEZ LES INSTRUCTIONS
D'INSTALLATION SE TROUVENT DANS LE MANUEL D'INSTALLATION.
DIRECT VENT GAS FIREPLACE. SUITABLE FOR BEDROOM, BATHROOM AND BED-SITTING ROOM
INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE WITH THE
CURRENT STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES, IN CANADA
OR IN THE UNITED STATES THE MANUFACTURED HOME CONTRUCTION AND SAFETY
STANDARD, TITLE 24 CFR, PART 3280. WHEN THIS US STANDARD IS NOT APPLICABLE USE
THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTURED HOME INSTALLATIONS,
SITES AND COMMUNITIES, ANSI / NFPA 501A. WHEN INSTALLED WITH SCREEN KIT GD-565KT,
THE FIREPLACE COMPLIES WITH CGA CERTIFICATION REQUIREMENT CR95-006.
FOR USE
ONLY WITH BARRIER W565-0178. FOLLOW THE INSTALLATION INSTRUCTIONS LOCATED IN
THE INSTALLATION MANUAL.
BGD36CFNTR
BCDV36CFNTR
MODEL
BGD36CFPTR
BCDV36CFPTR
0-4500FT (0-1370m)
ALTITUDE / ELEVATION
0-4500FT (0-1370m)
17,000 BTU/h
INPUT / ALIMENTATION
17,000 BTU/h
12,000 BTU/h
REDUCED INPUT / ALIMENTATION REDUITE
12,000 BTU/h
59.4% P4 59.4%
MANIFOLD PRESSURE:
3.5" WATER COLUMN
MANIFOLD PRESSURE:
10" WATER COLUMN
PRESSION AU COLLECTEUR:
3.5" D'UNE COLONNE D'EAU
PRESSION AU COLLECTEUR:
10" D'UNE COLONNE D'EAU
MINIMUM SUPPLY PRESSURE:
4.5" WATER COLUMN
MINIMUM SUPPLY PRESSURE:
11" WATER COLUMN
PRESSION D'ALIMENTATION MINIMALE:
4.5" D'UNE COLONNE D'EAU
PRESSION D'ALIMENTATION MINIMALE:
11" D'UNE COLONNE D'EAU
MAXIMUM SUPPLY PRESSURE:
7.0" WATER COLUMN
MAXIMUM SUPPLY PRESSURE:
13" WATER COLUMN
PRESSION D'ALIMENTATION MAXIMALE:
7.0" D'UNE COLONNE D'EAU
PRESSION D'ALIMENTATION MAXIMALE:
13" D'UNE COLONNE D'EAU
9700539 (WSL)
4001657 (NGZ)
4001658
(NAC)
4001659
(WUSA)
W385-1974
NOT FOR USE WITH SOLID FUEL. FOR USE WITH GLASS
DOORS CERTIFIED WITH THIS UNIT ONLY.
WARNING:
THIS FIREPLACE USES AND REQUIRES A FAST ACTING THERMOCOUPLE. REPLACE ONLY
WITH A FAST ACTING THERMOCOUPLE SUPPLIED BY WOLF STEEL LTD.
DO NOT ADD ANY MATERIAL TO THE APPLIANCE, WHICH WILL COME IN CONTACT WITH THE FLAMES, OTHER
THAN THAT SUPPLIED BY THE MANUFACTURER WITH THE APPLIANCE.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS /
DEGAGEMENTS MINIMAUX DES MATERIAUX COMBUSTIBLES:
TOP/ DESSUS
0
RECESSED DEPTH / PROFONDEUR D'ENCASTRE
17.25"
FLOOR / PLANCHER
0
VENT SIDES / COTES DE L'EVENT
1"
SIDES / COTES
0
VENT TOP / EVENT SUPERIEUR
2"
BACK / ARRIERE
0
VENT BOTTOM / EVENT INFERIEUR
1"
MANTEL / MANTEAU
12" *
* MAXIMUM HORIZONTAL EXTENSION / L'EXTENSION HORIZONTALE MAXIMALE: 2". SEE INSTRUCTION
MANUAL FOR GREATER EXTENSIONS. REFERER AU MANUEL D'INSTRUCTION POUR DES EXTENSIONS PLUS
GRANDES.
SEE OWNER'S INSTRUCTION MANUAL FOR MINIMUM AND MAXIMUM VENT LENGTHS.
REFERER AU MANUEL D'INSTALLATION DE PROPRIETAIRE POUR LES LONGUEURS D'EVACUATION
MINIMALE ET MAXIMALE.
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA
UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE UTILISE AVEC CET
APPAREIL. UTILISER AVEC LES PORTES VITREES
HOMOLOGUEES SEULEMENT AVEC CETTE UNITE.
AVERTISSEMENT:
CE FOYER UTILISE ET REQUIERT UN THERMOCOUPLE À ACTION RAPIDE. REMPLACEZ
UNIQUEMENT AVEC UN THERMOCOUPLE À ACTION RAPIDE DE WOLF STEEL LTÉE. N’AJOUTEZ PAS A CET
APPAREIL AUCUN MATERIAU DEVANT ENTRER EN CONTACT AVEC LES FLAMMES AUTRE QUE CELUI QUI
EST FOURNI AVEC CET APPAREIL PAR LE FABRICANT.
THE APPLIANCE MUST BE VENTED USING THE APPROPRIATE WOLF STEEL VENT KITS. SEE OWNERS
INSTALLATION MANUAL FOR VENTING SPECIFICS. PROPER REINSTALLATION AND RESEALING IS NECESSARY
AFTER SERVICING THE VENT-AIR INTAKE SYSTEM.
L'APPAREIL DOIT EVACUER SES GAZ EN UTILISANT L'ENSEMBLE D'EVACUATION PROPRE A NAPOLEON.
REFERER AU MANUEL D'INSTALLATION DE PROPRIETAIRE POUR L'EVACUATION PRECISE. IL EST IMPORTANT
DE BIEN REINSTALLER ET RESCELLER L'EVENT APRES AVOIR ASSURE LE MAINTIEN DU SYSTEME DE PRISE
D'AIR.
DECORATIVE PRODUCT: NOT FOR USE AS A HEATING APPLIANCE
PRODUIT DÉCORATIF: NE PAS UTILISER COMME APPPAREIL DE CHAUFFAGE.
ELECTRICAL RATING / CLASSIFICATION: 115V 0.82AMP, 60HZ
OPTIONAL FAN KIT / ENSEMBLE DE VENTILATEUR FACULTATIF: GZ550-KT, GD65
72
W415-1516 / A /10.22.15
FR
2.4
INFORMATION À PROPOS DE LA PLAQUE D’HOMOLOGATION
INSTALLATEUR : Il est de votre responsabilité de cocher les cases appropriées sur la plaque
d'homologation correspondant au modèle, au type d'évacuation et au type de gaz de l'appareil.
Pour l’emplacement de la plaque d’homologation, voir la section « VUE D’ENSEMBLE DE L’INSTALLATION ».
Cette illustration est à titre de référence seulement. Consultez la plaque d’homologation pour obtenir
l’information précise.
NOTE: La plaque d’homlogation doit rester avec l’appareil à tout instant. Il ne doit pas être enlevé.