ARCHITECTURAL AND ENGINEERING SPECIFICATION, v 2.7
21
a. It will be possible for the system operator to initiate a manual dial out
connection to any controller connected via telephone line, at any time.
b. Controllers connected to the system via telephone lines may initiate
dial in connections to their host PC in case they detect alarm events
that have been previously programmed as high priority events.
c. Controllers connected to the system via telephone lines may initiate
dial in connections to their host PC in case the controller (Access
Control Panel) transaction buffer is 75% full.
d. Controllers being communicated with over telephone lines will be able
to be password protected.
e. The system shall support a minimum of two dial-out lines.
f. The system shall support a minimum of two dial-in lines.
2.7. SYSTEM SOFTWARE FEATURES
A.
Anti-Pass back:
1. The system shall support the following modes of anti-passback:
a.
Global System Wide Anti-Passback:
The user may enter at any IN
reader and/or leave using any OUT reader in the system. Up to 250 +
Anti-Passback areas shall be supported.
b.
Hard Anti-Pass back:
The cardholder will not be able to use his/her
card consecutively at either an In or an Out reader. Doing so will
generate an event message and the system will deny access to the
cardholder. The cardholder must be In before swiping Out, and vice-
versa.
c.
Soft Anti-passback:
Will allow the cardholder to access an (In) or
(Out) door consecutively, but the system will generate an error
message.
d.
Duration Use (timed) Anti-Passback:
The system shall have the
capability to restrict the use of an In or an Out reader for a particular
card-holder, for a certain duration of time. When applied to an APB
type reader, this duration will determine the amount of time (minutes)
that a badge that is in APB violation, will be rejected. If a badge is
rejected due to APB violation, the use of this badge in the same
direction-type reader will continue to be rejected until the duration use
time expires. After the expiration, the badge holder will be permitted
passage at the reader.
e.
Nested Anti-Passback:
The system shall support multiple zones of
anti-passback within the same building I.E. Independent zones of anti-
passback where one in read from one zone does not affect another
zones setting.
f.
APB Reset:
The system shall be capable of a global reset of all
cardholders in the system. This can be done by schedule, or manually.
g.
Nested Anti-Passback:
The system shall be capable of nested anti-
passback.