background image

 
 
 
 

ARCHITECTURAL AND ENGINEERING SPECIFICATION, v 2.7  

 

 

 
 
 

PREFACE 
 

 

The Continental Access 

CardAccess 3000 Architectural & Engineering Specification 

is designed to 

serve as a guide for specifying a Continental Access state of the art integrated Access control, alarm, 
security, video management system. 

This document is available free of charge in both printed 

form and electronic media. 

 

CardAccess 3000 

 

 

 

CardAccess 3000 will be a full-featured enterprise class access control solution, providing a 
scalable solution from stand-alone entry level through networked world class enterprise 
systems. This multi-tiered systems approach will provide for modular expansion and growth 
as required, and is designed to provide cost-effective system with expansion and functional 
enhancements. 

 

Key Features 
 

  A seamless integrated interface for Access Control, Alarm Monitoring, DVR/NVR 

Interface, Visitor Management Control, Time and Attendance/Payroll Functions, Photo 
Badging, Import/Export Utilities, Email/SMS Notification, Threat Level Management, 
Napco Security/Fire Interface and Open API support. 

  26 to 200 bit card formats plus FIPS 201-1 and NIST 800-116 compliancy.  

  Secure MSDE/MSSQL technology and open database information sharing with CA 

ExchangeDB Import and Export features. 

  Scalable, flexible architecture of robust enterprise-class software provides an easy to use 

and easy to install solution for any size facility with unsurpassed down load speeds. 

  Interoperability for all the functions required in today's increasingly stringent security 

environment in one easy-to-use graphical workstation interface. 

 

More Information 
 

Continental Access reserves the right to modify these specifications at any time. Changes 
and updates to this document will be made available as they are released. For the latest 
release of this document, check the Continental Access web site 

www.continentalaccess.net

or call Continental Access at (631) 842-9400 to talk to a sales representative for information 
on the latest release. Technical Assistance on preparing specific project applications is 
available by calling (631) 842-9400. 

 
 
 
 
 
 
 
 

Summary of Contents for CARDACCESS 3000 - ARCHITECTURAL AND ENGINEERING SPECIFICATION V2.7

Page 1: ...N v 2 7 1 CardAccess 3000 Architectural Engineering Specification Version 2 7 Continental Access A Division of the Napco Security Group 355 Bayview Avenue Amityville New York 11701 Phone 631 842 9400...

Page 2: ...ng Import Export Utilities Email SMS Notification Threat Level Management Napco Security Fire Interface and Open API support 26 to 200 bit card formats plus FIPS 201 1 and NIST 800 116 compliancy Secu...

Page 3: ...PANEL 1 9 ALTERNATES 1 10 DEALERS 1 11 CONTRACTOR 1 12 DEFINITIONS 1 13 MERITS AND FUTURE GROWTH 1 14 SUBMITTALS 1 15 QUALITY ASSURANCE 1 16 WARRANTY 2 PRODUCT 2 1 PC REQIREMENTS 2 2 SYSTEM DESCRIPTI...

Page 4: ...y Tags Key Fobs I O Boards Power Supplies as specified herein All material will be listed in Continental Access catalogs 1 2 SYSTEM REQUIREMENTS A Acceptable Manufacturers Shall Be with no alternative...

Page 5: ...rds utilizing the 200 bit format 6 IPV IV and IPV VI Ethernet communications 7 Support AES 128 256 encryption 8 Time zone offsets 9 Reporting alarms to a central monitoring station via Ethernet withou...

Page 6: ...be available as either a hardware or software key C Security key will not be required at workstations D The Security key will determine both hardware and software limitations 1 Hardware License Limit...

Page 7: ...elligent Reader Control Panel 2 Four Door Intelligent Reader Control Panel 3 Eight Door Intelligent Reader Control Panel 4 Expansion Modules i The ACS panels shall provide for full Supervised Alarm In...

Page 8: ...r prior to the bid C All bidders must have 5 years installation experience on the ACS product lines D The Integrators of the ACS products shall have been in the Access Control business for a minimum o...

Page 9: ...ning ACS software Here an operator can program and monitor the security system operations F Access Control Panels These are the fully distributed hardware devices that store all data necessary to cont...

Page 10: ...which shall include the following 1 Manufacturer s data for all material and equipment including controllers local processors computer equipment access cards and any other equipment provided as part o...

Page 11: ...System start up and shut down procedures 3 Use of system command and applications software 4 Recovery and restart procedures 5 Graphic alarm presentation 6 Use of report generator and generation of re...

Page 12: ...e shall be a local representative and factory authorized local service organization which will carry a complete stock of parts and provide maintenance for these systems Local shall be defined as an ar...

Page 13: ...ating System Microsoft Windows 2000 Professional Server or Advanced Server w SP4 Win XP Pro w SP2 or Win 2003 Microsoft Windows 2000 Professional Server or Advanced Server w SP4 Win XP Pro w SP2 or Wi...

Page 14: ...y right clicking and choosing live video 4 Unlock and lock doors from the dynamic maps 5 Turn on off devices from the dynamic maps 6 Respond to alarms from the dynamic maps 7 Add and delete dynamic ma...

Page 15: ...password for each COM port b When operating in this mode the ACS door controllers will not accept communications from any host PC workstation or communications server that does not provide the correc...

Page 16: ...ing Management 5 CCTV Integration Management 6 System Administration Management except archiving 7 Personnel Tracking Management Reports 8 Visitor Management 9 Conditional Badging Management 10 Muster...

Page 17: ...s from 26 bit to 256 bits 8 Storing up to 1 000 000 card holder records 9 Reading the FIPS 201 1 PIV TWIC and CAC card formats 10 Shall be capable of Time Zone Offsets for those panels deployed in dif...

Page 18: ...use initial password which must be changed by the operators when they log on Operators will be allowed to change their passwords any time Operator password invalidation will be required in cases of s...

Page 19: ...of the record changed 2 The audit trail shall track event messages record additions deletions and revisions The record will contain a date time stamp for the change the logged on operator s name table...

Page 20: ...or remote polling The system shall support the following alternative communications modes 1 Network a All communications shall be capable of AES 128 256 bit encryption b The system shall have the capa...

Page 21: ...e his her card consecutively at either an In or an Out reader Doing so will generate an event message and the system will deny access to the cardholder The cardholder must be In before swiping Out and...

Page 22: ...figurations 2 The system shall support the assignment of multiple operators to the same database partition 3 Database Partitioning should allow the administrator to assign each Operator Privilege to t...

Page 23: ...cripting vi View Toolbars vii Help CardAccess 3000 Help About CardAccess 3000 viii Alert Signal Menu Silence ix Control Menu Control Devices x Status Menu Remove Entry xi Remove Station Menu Remove Of...

Page 24: ...hoto Export Clear Photo Clear Signature Pin Keypad Pin Number Print Photo Copies Re Issue Remarks Note Field Shunt Group Shunt by Reader Shunt Inactive Shunt Shunting SSN Social Security Stay On Panel...

Page 25: ...ngle double sided printers The system software shall support many different printer driver manufactures and will be compatible with any of the following Continental Access printer models G Scheduled R...

Page 26: ...all allow the operator may choose to modify these default settings as required M Import 1 The system shall support importing of personnel data from other databases 2 The system shall be capable of rec...

Page 27: ...stem will be able to execute these scheduled changes without the need for operator intervention 2 The system also shall provide the operator the flexibility to control the scheduled change by a single...

Page 28: ...system 2 The administrator may partition the events by user Only events from the panels and readers in the operators partition will be viewable 3 Each priority will be uniquely identified by color tha...

Page 29: ...tation 10 Additional Alarms The system shall also generate alarms for the following a Enclosure tampering b Access Control Panel communication loss restore c Alarm tampering supervised d Alarms shall...

Page 30: ...stem operator will have the advantage of filtering events to display only the category of interest 16 Event display modes a Tracking Mode will allow the operator to view events activity displayed on t...

Page 31: ...ification establishing that every signed data object on the card was signed by a trusted issuer e g certificates fingerprint template facial image template to ensure they are genuine and not counterfe...

Page 32: ...rmation in the database c The system shall limit the number of readers to be programmed based on the panel type 5 Interactivity a The system software shall allow through the optional use of interactiv...

Page 33: ...re shall have the capacity for 255 user definable time schedules Each time schedule will allow for a maximum of 10 individual time intervals 2 Assignment The time schedules will be able to be assigned...

Page 34: ...access The system will then generate an alert that may be linked to control relays for the notification of the duress alarm 6 Door Alarms Each door may be programmed to generate FORCED DOOR and DOOR O...

Page 35: ...The system administrator will be able to enter a date in this field to disable the concerned badge automatically j Badge Use Limit The system administrator will be able to limit the number of times a...

Page 36: ...cardholder records by clicking on field titles and entering the criteria being looked for directly into the data field 6 Alarm Shunting The system shall facilitate shunting of alarms by allowing cert...

Page 37: ...t requiring operator input The help screen shall be accessible by using the standard Microsoft Windows help system These help screens shall contain context sensitive information that will allow the op...

Page 38: ...physical serial port for each NAPCO panel to be connected via serial communications or the NAPCO panel must be capable of interfacing over an existing network via a Napco Netlink TCP IP interface modu...

Page 39: ...shall be able to perform all viewing playback and video storage functions simultaneously 3 The system shall allow video to be displayed on the same CardAccess 3000 monitor and configuration can be per...

Page 40: ...be possible with the help of the fully integrated DVR RemoteView window running along with the CardAccess 3000 GUI 14 The system shall display a minimum of four video windows for viewing remote camer...

Page 41: ...ction shall provide for an activation date at which time the visitor badge will become enabled and an expiration date at which time the badge will become disabled OO Badging 3000 Video Badging 1 The o...

Page 42: ...easily copy cut and paste elements between multiple design windows g Duplex printing with user definable printing modes h Will select background color from standard and custom palettes i Vertical text...

Page 43: ...uress Access s Denied Void Badge t Denied Facility Match u Denied Time Of Day v Denied Issue Level w Denied Unauthorized x Denied PIN Violation y Denied APB IN OUT z Denied Escort Match aa Denied Reis...

Page 44: ...ncrements in seconds up to 59 and then in minutes only up to 60 c The system shall allow for the same manual control over relays TT Application Programming Interface 1 The system shall provide for an...

Page 45: ...roprocessor from relay generated transients e Electrical Surge Protection The controller shall have Built In electronic surge protection devices to protect controller circuitry to which external conne...

Page 46: ...o 10 custom card formats The Access Control Panel will be able to read the format of most Magnetic Stripe Bar Code Proximity or Wiegand Effect encoded cards and will allow an operator to specify parit...

Page 47: ...nels will continue to function without any degradation in operation and will provide storage for a minimum of 20 000 cardholders and at least 1000 transactions b Modem Communication The aforementioned...

Page 48: ...and appurtenances in accordance with Continental Access instructions and shall furnish all necessary interconnections services and adjustments required for a complete and operable system as specified...

Page 49: ...and in no case shall notice be given until after the contractor has received written approval of the specific test procedures Test procedures shall explain in detail step by step actions and expected...

Page 50: ...s keyboards system printers peripheral equipment ACS equipment power supplies and electrical and mechanical controls 2 Clean system equipment including interior and exterior surfaces 3 Perform diagnos...

Reviews: