Installing the collectors
22
protection.
>
Remove transport protection from the collector connec-
tions.
>
Insert the hydraulic plug-in connector into the collector.
[1.]
>
Push the second collector as far as it goes to the first
collector. [2.]
>
vv the clamps over both plug-in connectors. [3.]
6720816962-23.1ST
2.
3.
1.
3.
Fig. 53 Ensure first and second collectors are together.
>
Tighten the screw of the double-sided collector clamp
with a 5 mm Allen key.
The clamp must engage in the recesses of the collector
profile.
6720816962-24.1ST
Fig. 54 Fastening the double sided collector clamp
CAUTION: Risk of injury and leaks
through escaping solar heat transfer
medium as a result of unsecured plu-
gin connectors.
>
Secure hydraulic collector connection with
clips.
>
Fit all other collectors in the same way.
8.1.5 Fitting single sided collector clamps on the right hand
side
>
Push the collector clamp into the profile rail and let it
click into the slot. [1.]
>
Counterhold the clamp. [2.]
>
Tighten the screw of the collector clamp with a 5 mm
Allen key. The clamp must engage in the recesses of the
collector profile. When the screw is tightened, the plastic
guide breaks at the pre-determined cut-off points. [3.]
6720816962-35.1ST
1.
3.
1.
2.
Fig. 55 Fitting the collector clamp