TDMA CONTROL 602-702 Eng Nov.doc
48
5.15
CONTROL 702: Example
Function
Sele
ctio
n
Sub-
secti
on:
Cannot be
combined with:
F
Sensor Allocation
A Output Allocation
Solar pump with &
without top loading
X BF -
1
2
3
Collector Sensor
Store Bottom (F)
Store Top (A; B)
1 Collector pump
230V
East-West
SF 5 -
11 Collector Sensor 2
2 Collector pump 2
230V
Yield Measurement
AF 4 -
9
10
Yield Sensor (Cold)
Yield Sensor (Hot)
-
-
Radiation Measure
AF 7 -
ES Radiation Sensor
-
-
Sol
ar
F
un
cti
on
Frost Protection
AF 6 -
17 Frost Sensor
1 Collector pump
230V
* Twin Store
(Priority, Equal),
Swimming Pool
SF 6 -
3
15
Store top (A; B)
Store 2 Bottom
3 Cooling
230V
Cool
in
g
** Cooling via
Heating Circuit
SF 6
Twin Store
(Priority, Equal),
Swimming Pool
3 Store Top (A; B)
9
10
11
Pump Heating circ 1
Mixer Close HC1
Mixer Open HC1
230V
DHW Heating with
Separate Output
SF 7 -
3 Store Top (A; B)
18 DHW Heating
0-
10V
Circulation
AF 3 -
- -
5 Circulation pump
230V
DH
W
Circulation/ Bath
Button
BF
-
D2 - Digital Input 2
- Circulation pump
230V
Bo
il
er
Boiler Control for
DHW & Heating
AF 1 -
3
12
16
Store Top (A; B)
Boiler Sensor
Ambient Temperature
19 Boiler Demand
0-
10V
Ht
g
Pump Control for
Boiler & Heating
AF 2 -
12 Boiler Sensor
6 Boiler pump
230V
Heating Circ 1 /
Mixer Vv & Pump
Control
SF 1 -
6
16
Heating Flow 1
Ambient Temp Sensor
9
10
11
Pump Heating Cir 1
Mixer Close HC1
Mixer Open HC1
230V
Heating Circ 2 /
Mixer Vv & Pump
Control
SF 2 -
7
16
Heating Flow 2
Ambient Temp Sensor
12
13
14
Mixer Close HC2
Mixer Open HC2
Pump Heating Cir 2
230V
Heating Circ 3 /
Mixer Vv & Pump
Control
SF 3 -
8
16
Heating Flow 3
Ambient Temp Sensor
15
16
17
Mixer Close HC3
Mixer Open HC3
Pump Heating Cir 3
230V
Bufferlogic
SF 4
Return Temp
Raising
4
5
Buffer Sensor 1
Buffer Sensor 2
-
-
Hea
ti
ng
S
up
p
o
rt
Return Temp Raising
SF 4 Bufferlogic
4
5
Heating Return
Store Heating Return
7 Return Temp Raising 230V
Solid Fuel Boiler
SF 8 T-Pro 2
13
14
Solid Fuel Blr Sensor
Store Solid Fuel Blr
8 Solid Fuel Boiler
230V
T-Pro
AF 5 -
18
19
T-Pro Sensor 1
T-Pro Sensor 2
4 T-Pro
230V
T-Pro 2
SF 8 Solid Fuel Boiler
13
14
T-Pro 2 Sensor 1
T-Pro 2 Sensor 2
8 T-Pro 2
230V
Temp
.-
Con
tr
ol
T-Pro 3
SF 7
DHW Heating
with Separate
Output
20
21
T-Pro 3 Sensor 1
T-Pro 3 Sensor 2
18 T-Pro 3
230V
Heat Meter 1
SF 9 Thermostat HC 1 D3 Digital Input 3
-
-
Heat Meter 2
SF
10 Thermostat HC 2 D4 Digital Input 4
-
-
Heat Meter 3
SF
11 Thermostat HC 3 D5 Digital Input 5
-
-
Flowmeter for Solar
Output Measurement
BF
D1 Digital Input 1
-
-
BF = Basic function (always active); AF1…AF7 = Additional Function (activate); SF1…SF11 = Select Function (one
function can be activated); A, B, C, D, E and F: SOLUS II Sensor Sleeve Positions; *Only when Cooling is set,
**Only with activated heating circuit control.