Enter the following key combination to do so:
81 03 to 10 incorrect entries
*
01 to 99 minutes
#
Example for setting 6 incorrect entries after which the code lock is to be blocked for
87 minutes:
81 06
*
87
#
The alarm block can be deactivated using a valid ID card, by entering a valid code or with
a valid card + user number.
☞
Factory setting = after 10 invalid ID cards, 10 incorrect entries of the
code of 1 valid ID card and then 5 incorrect user number entries. The
code block is set to 1 minute. The yellow LED is lit once and the
buzzer sounds once at 10 second intervals while the block is active.
As soon as the block is deactivated the buzzer emits a long beep
tone.
8.13 Door State Monitoring
Enter the following key combination to deactivate this function:
9
00
#
Enter the following key combination to activate this function:
9
01 to 99 seconds
#