Connect Tech Blue Heat/Net User’s Manual
Revision 0.13
101
Using SCM/TCM
Log onto the Blue Heat/Net. The default login for the TCM is
root.
(There is no login necessary
if using SCM.) The default password for both TCM and the SCM is
password
.
Enter
net net=198.182.196.0.
This will set 198.182.196.0 to the server, gateway and the unit’s IP
in one step.
Enter
net my_ip=15.
This will set the unit’s IP to 198.182.196.15.
Enter
net server_ip=1.
This will set the server IP to 198.182.196.1.
Enter
net gateway_ip=2.
This will set the gateway IP to 198.182.196.2.
Enter
net subnetmask=255.255.255.0.
This will set the subnet mask.
Enter
net dns_ip=3.
This will set the DNS IP to 198.182.196.3
Enter
net dhcp=no.
This will turn off DHCP on the unit.
Enter
save.
This will save the configuration set above to flash memory.
Enter
exit.
The unit will reboot using the new settings.
Using WCM
Connect to the Blue Heat/Net using a web browser by entering the current IP of the unit in the
address.
Log on by supplying the username and password. The default login is
wcm
and the default
password is
password
.
Select the
Blue Heat/Net Settings
page and fill in the server IP, Blue Heat/Net IP, Gateway IP,
DNS IP and subnet mask as defined above.
Ensure the Use DHCP option is set to
no
Click on the
Save to Flash
button to store the changes.
DHCP Setup
In many modern networks IP numbers are not static but are automatically assigned by a DHCP
server and can change over time or on each power up.
DHCP must be enabled on the Blue Heat/Net because it is shipped to use a default static IP
(192.168.42.1)
Using SCM/TCM
Log onto the Blue Heat/Net. (If using the SCM, no login is required. For the TCM, the default
login is
root
.) The default password for both SCM and TCM is
password
.
Enter
net dhcp=yes.
This will turn on DHCP on the unit.
Enter
net dns_ip=3.
This will set the DNS IP to 198.182.196.3
Enter
save.
This will save the configuration we just set to flash memory.
Enter
exit.
The unit will reboot using the new settings.