33
cfg
Syntax:
cfg [port=] [timeout=] [password=] [prompt=] [file=]
Description:
Establishes the settings used by the SCM application to
modify its behavior.
Options:
port=
Specifies the port number to scan for a password to gain entry in the SCM.
N
= Scan just port N (N=1 to the number of ports on the unit).
255
= Scan all ports on the unit (default unless unit has programmable line
interfaces).
timeout=
Specifies the time duration allowed for a TCM (via telnet) session to be idle (no
activity) before the session is terminated.
0 to 1092 minutes
(default = 5)
Note: A setting of zero allows infinite timeout.
password=
This sets the password phrase, which is used to gain access to the SCM, TCM
and WCM modes of configuring the Blue Heat/Net. The default is “password”.
prompt=
This setting controls whether a password prompt (and other password entry
status information) is presented to the terminal. This prompting is helpful for
new users of the product but may present a problem when other devices are
connected to the serial port.
yes
enables
the
password prompting (default)
no
disables the password prompting
file=
This sets the file name used as a default when using the
flldr
command.
It can be any sequence of characters up to 128 characters in length. (The default
is “BHNloader_vvv.gz”, where vvv is the current version number of the
“Loader”).
exit
Syntax:
exit [-nosave] [-no_reset][-login]
Description: This command is to exit the SCM and reboot the Blue Heat/Net. If CDS changes
have been made a warning message is issued and the SCM will not exit.
Options:
-nosave
Exit without saving changes (abandon changes).
-no_reset
Exit SCM without rebooting, maintaining the changes to settings for this session
only. (Booting is continued after the SCM is exited.)
-login
Exit without saving changes, and restart the SCM login process.