49
Dealing:
• The Conel Stream must not be exposed to avoidable shocks or collisions;
Temperature ranges
of the media to be
promoted:
• Temperature conveying medium: > (frost-free) up to + 40°C.
Operation:
• The Conel Stream is suitable for continuous operation.
• Prolonged operation of the Conel Stream with a throughput below the
minimum value indicated on the data sheet can cause excessive heating
that is harmful to the pump.
• At water temperatures close to 400C, the minimum throughput must be
increased depending on the temperature. For liquids other than water,
please contact Customer Service.
Attention:
Under no circumstances must the Conel Stream be „dry“ (i.e. in the dry state) - Dama-
ges are most likely the result.
1.4.2.7 Media quality of the water
hydrological data
maximum
Units
PH value
6.0 -8.0
conductivity
< 150
mS/m
total hardness
< 15
°dH
carbonate hardness
< 4
°dH
Chloride CL
< 100
mg/l
Sulfate So4
< 150
mg/l
Ammonium
< 1
mg/l
Iron Fe
< 0.2
mg/l
Manganese
< 0.1
mg/l
solid amount (sand)
< 150
g/m3
solid size
< 2.0
Mm