57
3.3
OPERATING DATA CONEL STREAM
Property
Conel Stream
Noise level
58db
Insulating material class motor
Class F
Temperature conveying medium
+15°C - +40°C
Drinking water connection
DN 17 / max. 4 bar
Max. plant pressure
6 bar
Max flow rate in RW operation
4.8m3/h
Max flow rate in TW operation
4.0m3/h at 4 bar
Quality conveying medium
Clean, free of solids or grinding particles, non-viscous, non-ag-
gressive, non-crystallized and chemically neutral, similar to the
properties of water
Manual switching mode
Yes
Pump switching machine
With pressure-dependent switch-on and flow-dependent
shutdown
Class
IP 42
Energy consumption Standby
approx. 1.4 W
Valve
Yes, integrated in the pump switching machine
Shock absorbers
Yes, integrated in the pump switching machine
Pressure gauge
Yes, integrated in the pump switching machine
3.4
Q/H DIAGRAM CONEL STREAM
Chart 3.4.1.1 Q/H Chart Conel Stream