POWER SUPPLY
The mains voltage must not be interrupted (e.g. via a light switch).
If the leak protection system does not have a permanent power connection,
/
a possible leak may not be identified,
/
the water leak protection system cannot close in the event of a leak.
5.4
INSTALLATION DIMENSIONS
The leak protection system can be installed in horizontal or vertical pipes.
A splash-proof socket, complying with the legal regulations for wet areas, is re-
quired for the power supply unit of the leak protection system and must be posi-
tioned above the filter at a separation of at least 1.5 m!
Fig. 2: Installation dimensions
Installation dimension
CLEAR STOP
A: Installation length with fittings
195
B: Device width
203
All dimensions in [mm] (see fig. 2)