Operation Manual
Regulator
4 kW 560 V DC 40% Duty Cycle + 24 V DC
BAL9100-0126d-EN
www.conductix.com
original document
page 29 of 32
14
Accessories
14.1
Power Input X1
The power input of the Regulator must be connected to a suitable Pickup. The use of an extension cable between the Regulator
and the Pickup is generally not allowed.
Both Regulator and Pickup strongly depend on each other. Please refer to both operating manuals together. Limiting conditions for
one device limit the operation of the other, i.e. if the ambient temperature around a Regulator is higher than what is allowed in the
specifications, the maximum continuous power available will be decreased even if the Pickup itself is sufficiently cooled.
The corresponding Pickup for both Regulator versions described in this documentation must be
ordered separately through Conductix-Wampfler, i.e. typically:
Material number: 91112-310-3090986
Only a suitable Pickup can be used on the power input X1.
14.2
Power Output X2
A 5 meter long cable, preassembled with one male connector on one side, can be ordered
separately through Conductix-Wampfler under material number:
91212-339-3047669.
Otherwise the following components are needed for the connection to the Regulator. Special tools are then needed for the
assembly. See chapter 15.
Description
Quantity
needed
Material Number
Ilme
Material Number
Harting
Hood (thermoplastic)
1
CQ08VK
19 12 008 0429
Cable gland (thermoplastic)
1
CRQ16
19 12 005 5157
Crimp terminal, male insert
1
CQM04/2
09 12 006 3041
Power crimp contact, male
1,5 mm²
2,5 mm²
5
(one type only!)
CXMA1.5
CXMA2.5
09 32 000 6104
09 32 000 6105
Control crimp contact, male
1,5 mm²
2,5 mm²
2
(one type only!)
CDMA1.5
CDMA1.5
09 15 000 6101
09 15 000 6106