Regulator
4 kW 560 V DC 40% Duty Cycle + 24 V DC
BAL9100-0126d-EN
www.conductix.com
original document
page 24 of 32
10.3
Signals and Meanings
Warning signals provide detailed information according to how they are displayed (LED blinking or not) and in which context (which
state for other LED’s/Relays). Refer to table 1 for information based on relay states and to table 2 when based on LED display.
Note that if the primary track supply is not on or if the Regulator is not correctly positioned over the primary track cable, all the
LED’s are off and all the relays are open:
(white): “24 V” LED off
(red):
“Error” LED off + “error” relay (pins 3 - 6) open
(orange): “Warning” LED off + “warning” relay (pins 3 - 5) open
(green): “Status” LED off + “status” relay (pins 3 - 7) open
If the above situation happens (all LED’s off + all relays open) despite the fact that the primary track is on and that the Pickup is
adequately positioned, then the Regulator or the Pickup is out of order.
WARNING!
Do not install an obviously damaged device. Do not take damaged devices into operation. Severe damage
may result. Ensure that protection device and other preventive measures taken comply with the applicable
regulations. Make sure that all connected circuits fulfill requirements for safe operation. Make sure that the
device cannot start up unintentionally.