Normal State
When a Regulator is
disabled
(primary track is on but Regulator turned OFF) the following information is available:
(white): “24 V” LED off *
(red):
“Error” LED off + “error” relay (pins 3 - 6) closed
(orange): “Warning” LED off + “warning” relay (pins 3 - 5) open **
(green): “Status” LED
blinking
+ “status” relay (pins 3 - 7)
open
When a Regulator is
enabled
(primary track is on and Regulator turned ON) and working under normal conditions of operation as
specified in this documentation, the following information is available:
(white): “24 V” LED on *
(red:)
“Error” LED off + “error” relay (pins 3 - 6) closed
(orange): “Warning” LED off + “warning” relay (pins 3 - 5) open**
(green): “Status” LED
on
+ “status” relay (pins 3 - 7)
closed
* note: the auxiliary 24 V / 5A DC (output 2) is provided through the voltage output 1 (though isolated), therefore it is available only
if the voltage output 1 is enabled. Typically, this corresponds to about 1 second after the enable signal is provided or at least to
less than 1 second once the green LED remains ON, once the “status” relay closes.
** note: A closed “warning” relay while the orange LED remains on does not necessarily indicate that the Regulator is being
operated under abnormal conditions; it may be that the Regulator operates in conditions close to its limits while still within its
specifications. Refer to paragraph 10.3 for more information about possible meanings of warning signals.