Operation Manual
Regulator
4 kW 560 V DC 40% Duty Cycle + 24 V DC
BAL9100-0126d-EN
www.conductix.com
original document
page 21 of 32
9
Warnings and Cautions
All electric work has to be carried out by qualified staff (IEC 364 respectively ENELEC HD 384 or DIN VDE
0100 and IEC 664 or DIN VDE 0110 and national safety rules).
Qualified staff, according to safety regulations, are persons that are familiar with the installation,
commissioning and operation of the energy supply systems and that have the appropriate qualifications.
The device is only foreseen to be operated in conjunction with matching IPT
®
components. If you are not
sure whether components match, contact Conductix-Wampfler. Do not put into operation before.
Do not install an obviously damaged device. Do not take damaged devices into operation. Severe damage
may result. Ensure that protection device and other preventive measures taken comply with the applicable
regulations. Make sure that all connected circuits fulfill requirements for safe operation. Make sure that the
device cannot start up unintentionally.
Route power and control cables separately so that no interference can occur. Only use cables with a cross-
section suitable for the given currents. Note polarity when connecting any device to the output of the
Regulators. If not observed, severe damage may result.
During or after operation surfaces of the Regulators and components nearby may be hot. Use caution!
Prevent access to hot surfaces if necessary.
Regulators can contain voltage even in a disabled mode (OFF), even if status LED’s have gone out. Do not
open, do not insert any objects inside, do not touch connection terminals. The only safe means of working
on circuits connected to the device is to ensure that the primary track is switched off and then to disconnect
physically the input and output plugs. Make sure that connections are not removed under dangerous
conditions, i.e. under load. Allow at least 5 minutes before touching connection terminals to be sure that no
energy remains stored internally by capacitors. Improper handling can result in electric shocks or burns as
well as damage to the Regulator.
Do not perform any work on or around the device while in operation.
Life threatening danger of electrical
shock!