background image

16

17

6.1 Preparing the skin
Body

Before you use the Lumilisse Hair Remover  on the body, your skin must 
be shaved (24 hours beforehand), clean, dry and free from any residue of 
powder or deodorant. Warning: Do not depilate (with an electric depilator, 
tweezers or waxing) before using Lumilisse Hair Remover. Epilating (remo-
ving hair from the root) would prevent intense pulsed light (IPL) treatment 
from having any effect. 

Face
Do not shave the diff erent areas of the face before use.

Before using the Lumilisse Hair Remover on the face, remove all traces 
of cream, lotion or makeup. Warning: Do not depilate (with an electric 
depilator, tweezers or waxing) before using the Lumilisse Hair Remover. 
Epilating (removing hair from the root) would prevent intense pulsed light (IPL) 
treatment from having any eff ect. 

6.2 Carrying out a test with the Lumilisse Hair Remover 
Carry out a test with the Lumilisse Hair Remover 48 hours before the fi rst use.

1.  Plug the adapter cord into the power jack on the handle of the Lumilisse Hair Remover (FIG. 1 

on the included Quick Start Usage Guide.)

2. Plug the other end of the adapter into a power outlet. 
 

>  The ON/OFF button turns on and is orange in color (FIG. 2).

3. Switch on the unit by pressing the ON/OFF button (FIG. 3). 
 

> The ON/OFF button turns green.

 

> T he power level 1 LED indicator is on. Level 1 is programmed by default when 

the unit is switched on (FIG. 4). 

4.  Place the unit Skin Sensor on the area of skin where you wish to perform the test (we 

recommend a leg) (FIG. 5).

 

>  The intensity level LED indicator(s) switch on and flash, showing that the unit 

has successfully detected the phototype of the area of skin to be depilated 
and has adjusted the power level automatically (FIG. 6). 

5. Press the trigger button on the handle once to confirm (FIG. 7).
 

>  The intensity level LED indicator(s) stop flashing (FIG. 8).

6.  Position the application surface on the area of skin detected and keep the application 

surface still, in position, to ensure total contact. 

 

>  The Ready LED flashes green when the unit is correctly positioned on the skin 

and ready to release a light pulse (FIG. 9).

7. Press the trigger button to release a light pulse onto the skin (FIG. 10).

NOTE:

 You may feel a 

slight

 hot sensation and tingling. This is normal.

8.  Move the application surface to another area of skin and press the trigger button to 

release another light pulse. Take care not to overlay the light pulses.

If you do not experience any abnormal reactions or discomfort 

(FIG. 11) 48 hours after the test, you may start treatment and move onto Chapter 6.3, “Treatment 
with Lumilisse Hair Remover.”

6.  Use of the Lumilisse Hair Remover 

If your skin does not react correctly to the test (FIG. 18), if you experience any abnormal 
reactions or discomfort after 48 hours, perform a second test at intensity level 1, whatever 
your phototype, without considering the Skin Sensor, and wait 48 hours (FIG. 19-20-21).

-  If you react correctly to this second test, proceed with the first treatment session, 

manually selecting level 1. 

-  If your skin does not react correctly to this second test, we recommend not using the 

appliance. 

For subsequent sessions, if there is absolutely no discomfort or side effects, you may 
gradually increase the power level over the sessions, with respect to the table below and 
using the intensity choice log to help you;

- Phototype I:  
- Phototype II:  
- Phototype III: 
- Phototype IV:  

6.3 Treatment with the Lumilisse Hair Remover 

We recommend that you always use the Skin Sensor on your skin before each depilation 
session and each change to the treatment area. Remember that different areas on the 
same limb may be different skin colors (e.g., inside wrist and top of underarm). When you 
first start out using the Lumilisse Hair Remover, start on your body, not your face, using 
the body attachment until you gain confidence using the unit.
1.  Plug the adapter cord into the power jack on the handle of the Lumilisse Hair Remover 

(FIG. 1 on the Quick Start Usage Guide included).

2. Plug the other end of the adapter into a power outlet. 
 

>  The ON/OFF button turns on and is orange in color (FIG. 2).

3. Switch on the unit by pressing the ON/OFF button (FIG. 3). 
 

> The ON/OFF button turns green.

 

>  The power level 1 LED indicator is on. Level 1 is programmed by default when the 

unit is switched on (FIG. 4). 

4.  Place the unit Skin Sensor on the area of skin where you wish to perform treatment 

(FIG. 12).

 

>  The intensity level LED indicator(s) switch on and flash, showing that the unit 

has successfully detected the phototype of the area of skin to be depilated 
and has adjusted the power level automatically (FIG. 13).

5. Press once on the trigger to confirm (FIG. 14).
 

>  The intensity level LED indicator(s) stop flashing (FIG. 15).

6.  Position the application surface on the area of skin detected and keep the application 

surface still, in position, to ensure total contact. 

 

>  The Ready LED flashes green when the unit is correctly positioned on the skin 

and ready to release a light pulse (FIG. 16).

7.  Press the trigger button to release a light pulse onto the skin (FIG. 17).

NOTE:

 You may feel a 

slight

 hot sensation and tingling. This is normal.

8.  Move the application surface to another area of skin and press the trigger button to 

release another light pulse. Take care not to overlay the light pulses.

ipl960f_18pg025882_ib_final.indd   16-17

ipl960f_18pg025882_ib_final.indd   16-17

3/13/18   8:12 AM

3/13/18   8:12 AM

Summary of Contents for Lumilisse IPL960F

Page 1: ...Fran ais Lumilisse IPL Hair Remover MODEL IPL960F Fran ipl960f_18pg025882_ib_final indd 1 ipl960f_18pg025882_ib_final indd 1 3 13 18 8 12 AM 3 13 18 8 12 AM...

Page 2: ...over won t start 9 2 There are no pulses when I press the release mechanism 9 3 Customer Service 10 Warranty pages 22 23 11 FAQ pages 23 24 12 Specifications page 25 13 Standards page 25 14 Electromag...

Page 3: ...ight Be sure to protect the skin treated with the Lumilisse Hair Remover with an effective sunscreen both during the treatment period and for at least 14 days past the last treatment session DO NOT US...

Page 4: ...the device at the skin and make sure it is in full contact with your skin before releasing a pulse Never use the Lumilisse Hair Remover on a material other than skin Never use the Lumilisse Hair Remov...

Page 5: ...hypotrophic Nonetheless the scar may be large and red hypertrophic or large and extended beyond the injured area keloid If scarring occurs consult your physician Change in pigmentation The Lumilisse...

Page 6: ...ity of hair growth in a treated area Hair grows in cycles see Section 5 and any increase in hair growth is generally temporary Please consult your doctor if you experience persistent or severe discomf...

Page 7: ...lts with the Lumilisse Hair Remover plan your sessions well in advance The Lumilisse Hair Remover features 5 levels of intensity running from the lowest level 1 to the highest level 5 The level of int...

Page 8: ...Leg 15 minutes Glide mode Back 5 minutes Glide mode Torso 5 minutes Glide mode Bikini line 2 minutes Precision mode Armpit 1 minute Precision mode Face 1 minute Precision mode NOTE The different oper...

Page 9: ...Remover 6 Use of the Lumilisse Hair Remover If your skin does not react correctly to the test FIG 18 if you experience any abnormal reactions or discomfort after 48 hours perform a second test at int...

Page 10: ...r skin You should ensure that the application surface of the Lumilisse Hair Remover is in full contact with your skin in order to allow it to glide If the application surface of the Lumilisse Hair Rem...

Page 11: ...umilisse Hair Remover on your face for the first few sessions once they have familiarized themselves with the instruction manual NOTE The Glide mode is not available for facial depilation You must wai...

Page 12: ...5 3 about the approximate duration of the session 4 Is the Lumilisse Hair Remover safe Your safety is our first priority When we designed the Lumilisse Hair Remover very strict standards were followe...

Page 13: ...xposure consult your doctor 16 What should I do before I use the Lumilisse Hair Remover Before each session with the Lumilisse Hair Remover it is important that the area to be treated has not been exp...

Page 14: ...ompliance level Electromagnetic environment guidance Electrostatic discharge ESD IEC 61000 4 2 8 kV contact 2 kV 4 kV 8 kV 15 kV air 2 kV for power supply lines 1 kV line s to line s 5 UT 95 dip in UT...

Page 15: ...smitters an electromagnetic site survey should be considered If the measured field strength in the location in which the Lumilisse Hair Remover IPL960F is used exceeds the applicable RF compliance lev...

Page 16: ...es Moisture protection Keep dry This appliance is not intended to be used near a flammable mixture of anesthetic and air or with oxygen or nitrous oxide 18PG025882 IB 14806 1 800 326 6247 www conair c...

Page 17: ...ipl960f_18pg025882_ib_final indd 32 ipl960f_18pg025882_ib_final indd 32 3 13 18 8 12 AM 3 13 18 8 12 AM...