Guidance and manufacturer’s declaration 

– electromagnetic immunity

The Lumilisse Hair Remover (IPL960F) is intended for use in the electromagnetic 
environment specifi ed below. The customer or the user of the Lumilisse Hair 
Remover (IPL960F) should assure that it is used in such an environment.

Immunity 

test

IEC 60601 

test level

Compliance 

level

Electromagnetic environment 

– guidance

Conducted RF
IEC 61000-4-6

Radiated RF
IEC 61000-4-3

3 V
0.15 MHz to 
80 MHz
6 V in ISM 
and amateur 
radio bands 
between 0.15 
MHz and 80 
MHz

10 V/m
80 MHz to 2.6 
GHz

3 V
0.15 MHz to 
80 MHz
6 V in ISM 
and amateur 
radio bands 
between 0.15 
MHz and 80 
MHz 

10 V/m

Portable and mobile RF 
communications equipment 
should be used no closer to any 
part of the IPL960F, including 
cables, than the recommended 
separation distance calculated 
from the equation applicable to 
the frequency of the transmitter.

Recommended separation 
distance

 
Where P is the maximum output 
power rating of the transmitter 
in watts (W) according to the 
transmitter manufacturer, and d 
is the recommended separation 
distance in meters (m).

Field strengths from fi xed RF 
transmitters, as determined by 
an electromagnetic site survey, 
a, should be less than the 
compliance level in each 
frequency range, b. Interference 
may occur in the vicinity of 
equipment marked with the 
following symbol:

NOTE 1:

       At 80 MHz and 800 MHz, the higher frequency range applies.

NOTE 2:

       These guidelines may not apply in all situations. Electromagnetic 

propagation is aff ected by absorption and refl ection from structures, objects 
and people.

a      Field strengths from fi xed transmitters, such as base stations for radio (cellular/
cordless) telephones and land mobile radios, amateur radios, AM and FM radio 
broadcasts and TV broadcasts cannot be predicted theoretically with accuracy. 
To assess the electromagnetic environment due to fi xed RF transmitters, an 
electromagnetic site survey should be considered. If the measured fi eld strength 
in the location in which the Lumilisse Hair Remover (IPL960F) is used exceeds 
the applicable RF compliance level above, the Lumilisse Hair Remover (IPL960F) 
should be observed to verify normal operation. If abnormal performance is 
observed, additional measures may be necessary, such as reorienting or relocating 
the Lumilisse Hair Remover (IPL960F).

b     Over the frequency range 150 kHz to 80 MHz, fi eld strengths should be less 
than 3 V/m.

Recommended separation distances between 

portable and mobile RF communications equipment and the 

Lumilisse Hair Remover (IPL960F)

The Lumilisse Hair Remover (IPL960F) is intended for use in an electromagnetic 
environment in which radiated RF disturbances are controlled. The customer or 
the user of the Lumilisse Hair Remover (IPL960F) can help prevent electromagnetic 
interference by maintaining a minimum distance between portable and mobile 
RF communications equipment (transmitters) and the Lumilisse Hair Remover 
(IPL960F) as recommended below, according to the maximum output power of the 
communications equipment.

Rated 

maximum 

output power 

of transmitter

(W)

Separation distance according to frequency 

of transmitter

(m)

150 KHz to 80 MHz

 80 MHz to 800 MHz

 800 MHz to 2.6 GHz

0.01

0.12

0.12

0.23

0.1

0.38

0.38

0.73

1

1.2

1.2

2.3

10

3.8

3.8

7.3

100

12

12

23

For transmitters rated at a maximum output power not listed above, the 
recommended separation distance d in meters (m) can be estimated using the 
equation applicable to the frequency of the transmitter, where P is the maximum 
output power rating of the transmitter in watts (W) according to the transmitter 
manufacturer.

NOTE 1:

   At 80 MHz and 800 MHz, the separation distance for the higher 

frequency range applies.

NOTE 2:

   These guidelines may not apply in all situations. Electromagnetic 

propagation is aff ected by absorption and refl ection from structures, objects 
and people.

ipl960f_18pg025882_ib_final.indd   28-29

ipl960f_18pg025882_ib_final.indd   28-29

3/13/18   8:12 AM

3/13/18   8:12 AM

Summary of Contents for Lumilisse IPL960F

Page 1: ...Fran ais Lumilisse IPL Hair Remover MODEL IPL960F Fran ipl960f_18pg025882_ib_final indd 1 ipl960f_18pg025882_ib_final indd 1 3 13 18 8 12 AM 3 13 18 8 12 AM...

Page 2: ...over won t start 9 2 There are no pulses when I press the release mechanism 9 3 Customer Service 10 Warranty pages 22 23 11 FAQ pages 23 24 12 Specifications page 25 13 Standards page 25 14 Electromag...

Page 3: ...ight Be sure to protect the skin treated with the Lumilisse Hair Remover with an effective sunscreen both during the treatment period and for at least 14 days past the last treatment session DO NOT US...

Page 4: ...the device at the skin and make sure it is in full contact with your skin before releasing a pulse Never use the Lumilisse Hair Remover on a material other than skin Never use the Lumilisse Hair Remov...

Page 5: ...hypotrophic Nonetheless the scar may be large and red hypertrophic or large and extended beyond the injured area keloid If scarring occurs consult your physician Change in pigmentation The Lumilisse...

Page 6: ...ity of hair growth in a treated area Hair grows in cycles see Section 5 and any increase in hair growth is generally temporary Please consult your doctor if you experience persistent or severe discomf...

Page 7: ...lts with the Lumilisse Hair Remover plan your sessions well in advance The Lumilisse Hair Remover features 5 levels of intensity running from the lowest level 1 to the highest level 5 The level of int...

Page 8: ...Leg 15 minutes Glide mode Back 5 minutes Glide mode Torso 5 minutes Glide mode Bikini line 2 minutes Precision mode Armpit 1 minute Precision mode Face 1 minute Precision mode NOTE The different oper...

Page 9: ...Remover 6 Use of the Lumilisse Hair Remover If your skin does not react correctly to the test FIG 18 if you experience any abnormal reactions or discomfort after 48 hours perform a second test at int...

Page 10: ...r skin You should ensure that the application surface of the Lumilisse Hair Remover is in full contact with your skin in order to allow it to glide If the application surface of the Lumilisse Hair Rem...

Page 11: ...umilisse Hair Remover on your face for the first few sessions once they have familiarized themselves with the instruction manual NOTE The Glide mode is not available for facial depilation You must wai...

Page 12: ...5 3 about the approximate duration of the session 4 Is the Lumilisse Hair Remover safe Your safety is our first priority When we designed the Lumilisse Hair Remover very strict standards were followe...

Page 13: ...xposure consult your doctor 16 What should I do before I use the Lumilisse Hair Remover Before each session with the Lumilisse Hair Remover it is important that the area to be treated has not been exp...

Page 14: ...ompliance level Electromagnetic environment guidance Electrostatic discharge ESD IEC 61000 4 2 8 kV contact 2 kV 4 kV 8 kV 15 kV air 2 kV for power supply lines 1 kV line s to line s 5 UT 95 dip in UT...

Page 15: ...smitters an electromagnetic site survey should be considered If the measured field strength in the location in which the Lumilisse Hair Remover IPL960F is used exceeds the applicable RF compliance lev...

Page 16: ...es Moisture protection Keep dry This appliance is not intended to be used near a flammable mixture of anesthetic and air or with oxygen or nitrous oxide 18PG025882 IB 14806 1 800 326 6247 www conair c...

Page 17: ...ipl960f_18pg025882_ib_final indd 32 ipl960f_18pg025882_ib_final indd 32 3 13 18 8 12 AM 3 13 18 8 12 AM...

Reviews: