MNC-0500-038
18 of 28
Revision 2
Amplifier Communication and Protocol, XTRT, Touchscreen TWTA
Parameter
Information Requested
Response Format
‘L’
Low Power Alarm/Fault
Trip point and setting
A XX.X in dBm (generate alarm)
F XX.X in dBm (generate fault)
D XX.X in dBm (disabled)
‘l’
Low Power Alarm/Fault
Trip point and setting
A XXXX in Watts (generate alarm)
F XXXX in Watts (generate fault)
D XXXX in Watts (disabled)
‘M’
Heater Hours
XXXXXX hours
‘N’
Beam Hours
XXXXXX hours
‘P’
Fwd Power
XX.X in dBm
‘Q’
Reverse Power
XX.X in dBm
‘X’
Antenna Power
XX.X dBm
‘x’
Load Power
XX.X dBm
‘R’
Reverse Power Alarm/Fault trip point and
setting
A XX.X in dBm (generate alarm)
F XX.X in dBm (generate fault)
D XX.X in dBm (disabled)
‘r’
Reverse Power Alarm/Fault
Trip point and setting
A XX.X in Watts (generate alarm)
F XX.X in Watts (generate fault)
D XX.X in Watts (disabled)
‘T’
TWT Temp — If you have a TWTA
Tube Temp — If you have an EIK
XXXX in
o
Celsius (Right Justified and Padded with Spaces.)
‘V’
Helix Voltage — If you have a TWTA
Beam Voltage — If you have an EIK
XX.X in KV
Notes:
1
Parameters ‘’Z’ and ‘z’ are only available with HPAs that have the linearizer option.
2.
Parameter ‘/’ is only applicable to Linearizers that have the Magnitude slope adjustment option.
EAR EXPORT CONTROLLED: The information contained in this Manual refers or relates to a product that is subject
to the U.S. Export Administration Regulations (EAR). Transfer of data herein by any means to a Foreign Person,