Operation
MNC-0400-071
Page 27 of 53
Revision 4
Note:
Firmware Revision .30 and later:
An additional feature has been added to the
event log to further aide visibility to events of interest. The events have been color coded
according to the following table:
Tag
Description
Example
local
An action initiated locally via touchscreen
input.
HV Disabled
remote
An action initiated remotely via serial or
ethernet.
HV Enabled
FAULT
A Fault condition which shut off High
Voltage.
Tube Overtemp
alarm
An condition occurred which did not require
HV off.
Maximum Power
Alarm
note
A comment entered by the operator.
BEGIN DOWNTIME
event
A state change.
FTD done: Standby
Table 1 – Color Coding of Events in the Event Log
EAR EXPORT CONTROLLED: The information contained in this Manual refers or relates to a product that is subject
to the U.S. Export Administration Regulations (EAR). Transfer of data herein by any means to a Foreign Person,
whether in the U.S. or abroad, may require an export license from the U.S. Department of Commerce.