XPA200-7984-I-OPT1, X-Band SSPA
Addendum
XPA200-7984-I-0PT1, Rev.2
7.1
Addendum
7.1 General
This addendum section contains additional items as listed
below:
1. Additional Troubleshooting helps (Table 7.1)
2. Wiring diagram.
3. Top level parts list.
7.2 Additional Troubleshooting Information.
Table 7.1
Additional Troubleshooting Help
SYMPTOM
POSSIBLE CAUSES
SOLUTIONS
Unit does not turn on
(no display, no front
panel lights, no
fans).
Power cord not plugged in.
Faulty wiring to 28V power
supply.
28V power supply fault.
Check power cord connections.
With input power cord
removed, check wiring and
connections to 28V power
supply.
Check output of 28Vdc power
supply.
Either one or both
fans do no turn on.
Faulty wiring, bad
Note: At power-up, the fans
are sequenced on. Therefore,
in normal operation, the
second fan does not turn on
until approximately 3 seconds
after the first fan.
Check AS/0206 to ensure that
Summary of Contents for XPA-200
Page 6: ......
Page 8: ......
Page 16: ......
Page 28: ......
Page 35: ......
Page 36: ......
Page 50: ......
Page 52: ......
Page 72: ......
Page 84: ...7 3 WIRING DIAGRAM next page ...
Page 85: ......
Page 86: ......
Page 87: ...XPA200 7984 I X Band SSPA Addendum XPA200 7984 I 0PT1 Rev 2 7 6 7 4 PARTS LIST next pages ...
Page 88: ......
Page 89: ......
Page 90: ......
Page 91: ......
Page 92: ......
Page 93: ......
Page 94: ......
Page 96: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX ...