XPA200-7984-I-OPT1, X-Band SSPA
Remote Control
Remote Control
XPA200-7984-I-OPT1, Rev.2
5-11
5.8.2 Configuration Commands
5.8.2.1 Amplifier ON/OFF
The XPA200-7984-I provides the user direct control of the 10
VDC supply voltage to the solid state RF power FETs. This
feature provides the ability to put the SSPA into a low power
consumption mode when the unit is offline. The default is on.
Amplifier control:
<DEV/AMP
_
xxx'cr'
xxx = ON or OFF
Confirmation:
>DEV/AMP
_
xxx'cr''lf']
Retrieve AMP Status:
<DEV/AMP
_
'cr'
Confirmation:
>DEV/AMP_xxx'cr''lf']
5.8.2.2 Mute Output
The user is provided output mute control via the remote
interface using this command. The default is on.
Mute Output:
<DEV/MUT
_
xxx'cr'
xxx = ON or OFF
Confirmation:
>DEV/MUT
_
xxx'cr''lf']
Retrieve Mute Status:
<DEV/MUT
_
'cr'
Confirmation:
>DEV/MUT_xxx'cr''lf']
5.8.2.3 Attenuator
The default is 10 dB.
Set Attenuator:
<DEV/ATT_ yy.yy'cr'
Confirmation:
>DEV/ATT
_
yy.yy'cr'lf']
Retrieve Attenuator::
<DEV/ATT
_
'cr'
Confirmation:
>DEV/ATT_ yy.yy'cr''lf']
Note:
yy.yy = 0.0 to 20.00 dB in 0.25 steps.
5.8.2.4 Auto Fault Recovery
The SSPA output is automatically muted in the event of a
detected fault. Auto Fault Recovery, if enabled, will cause the
output signal to go active (unmuted) if all faults clear. If
disabled, the output will remain muted even after all faults
clear until a MUT_OFF command is received (see 5.8.2.2). The
default is off.
Summary of Contents for XPA-200
Page 6: ......
Page 8: ......
Page 16: ......
Page 28: ......
Page 35: ......
Page 36: ......
Page 50: ......
Page 52: ......
Page 72: ......
Page 84: ...7 3 WIRING DIAGRAM next page ...
Page 85: ......
Page 86: ......
Page 87: ...XPA200 7984 I X Band SSPA Addendum XPA200 7984 I 0PT1 Rev 2 7 6 7 4 PARTS LIST next pages ...
Page 88: ......
Page 89: ......
Page 90: ......
Page 91: ......
Page 92: ......
Page 93: ......
Page 94: ......
Page 96: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX ...