XPA200-7984-I-OPT1, X-Band SSPA
Remote Control
Remote Control
XPA200-7984-I-OPT1, Rev.2
5-12
Set Fault Recovery: <DEV/AFR
_
xxx'cr'
xxx = ON or 0FF
Confirmation:
>DEV/AFR
_
xxx'cr''lf']
Retrieve Status:
<DEV/AFR
_
'cr'
Confirmation:
>DEV/AFR_xxx'cr''lf']
5.8.3 Status Commands
Status commands retrieve configuration, maintenance and
alarm status in summary form.
5.8.3.1 Configuration Status
Configuration Status:
<DEV/RCS_'cr'
Confirmation:
>DEV/RCS_'cr'
ATT_yy.yy'cr'
Attenuator
AMP_nnn’cr’
Amplifier - ON/OFF
TX_nnn'cr'
Transmit - ON/OFF
ONL_nnn'cr'
Online - ON/OFF
AFR_nnn'cr'
Auto Flt Recovery-ON/OFF
5.8.3.2 Maintenance Status
Maintenance Status:
<DEV/RMS_'cr'
Confirmation:
>DEV/RMS_'cr'
V+28_xx.x'cr'
+28 VDC Supply
V+12_xx.x'cr'
+12 VDC Supply
V-12_xx.x'cr'
-12 VDC Supply
V +5_x.x'cr'
+5 VDC Supply
V -5_x.x'cr'
-5 VDC Supply
V+10_1_xx.x'cr'
10 VDC Supply #1
V+10_2_xx.x'cr'
10 VDC Supply #2
TEMP_xx'cr'
Temperature
FPWR_xx.x'cr’
RF Forward Power (dBm)
RPWR_xx.x'cr''lf']
RF Reflected Power (dBm)
Summary of Contents for XPA-200
Page 6: ......
Page 8: ......
Page 16: ......
Page 28: ......
Page 35: ......
Page 36: ......
Page 50: ......
Page 52: ......
Page 72: ......
Page 84: ...7 3 WIRING DIAGRAM next page ...
Page 85: ......
Page 86: ......
Page 87: ...XPA200 7984 I X Band SSPA Addendum XPA200 7984 I 0PT1 Rev 2 7 6 7 4 PARTS LIST next pages ...
Page 88: ......
Page 89: ......
Page 90: ......
Page 91: ......
Page 92: ......
Page 93: ......
Page 94: ......
Page 96: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX ...