XPA200-7984-I-OPT1, X-Band SSPA
Installation
XPA200-7984-I-OPT1, Rev.2
2-5
2.3.1 Redundant Operation
and Setup
The system can operate in a standard 1:1 redundant
configuration by choosing VPC position 1 (SSPA A to antenna) or 3
(SSPA B to antenna) on the Mitec 2723B. For example, if the Mitec
2723B was set to run in Automatic mode and SSPA A was normally
operating to the antenna (VPC position 1), a fault on SSPA A would
cause the system to immediately switch to postion 3, or SSPA B to
antenna.
Each SSPA may have slightly different gain values. A
procedure to equalize gain and output power between SSPA A and SSPA
B for redundancy operation is described below. The output powers
from SSPAs A and B are first equalized by measurements at the load
port before switching power to the antenna port.
A. To set the output power of SSPA A:
1. Mute SSPA B via remote or front panel controls.(To
prevent unwanted power from SSPA B going to antenna.)
2. Set VPC to position 3 (B to antenna, A to load).
3. Connect a power meter to the Mitec calibrated load
measuring port (see 2723B test data for exact calibration
data). Adjust output power of SSPA A to desired level by
adjusting input RF power or by using the SSPA A attenuation
setting.
B. To set the output power of SSPA B:
1. Mute SSPA A via remote or front panel controls.(To
prevent unwanted power from SSPA A going to antenna.)
2. Set VPC to position 1 (A to antenna, B to load).
3. Connect a power meter to the Mitec calibrated load
measuring port (see 2723B test data for exact calibration
data). Adjust output power of SSPA B to desired level
(usually the same as A) by adjusting input RF power or by
using the SSPA B attenuation setting.
C. Choose the unit desired to be on-line.
1. Mute both units to prevent unwanted power from going to
the antenna.
2. Choose SSPA A (position 1) or SSPA B (position 3) for
operation to the antenna. The other unit will be sent to
the load.
3. Set the Mitec unit in Automatic mode and un-mute the
SSPAs.
4. Verify proper output power going to antenna by
connecting a power meter to the Mitec Antenna Forward power
measuring port (see Mitec test data for calibration factor).
Summary of Contents for XPA-200
Page 6: ......
Page 8: ......
Page 16: ......
Page 28: ......
Page 35: ......
Page 36: ......
Page 50: ......
Page 52: ......
Page 72: ......
Page 84: ...7 3 WIRING DIAGRAM next page ...
Page 85: ......
Page 86: ......
Page 87: ...XPA200 7984 I X Band SSPA Addendum XPA200 7984 I 0PT1 Rev 2 7 6 7 4 PARTS LIST next pages ...
Page 88: ......
Page 89: ......
Page 90: ......
Page 91: ......
Page 92: ......
Page 93: ......
Page 94: ......
Page 96: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX ...