Remote Control Operation
SMS-758 Modem Protection Switch
B–4
MN/SMS758 Rev. 3
B.3 Configuration Commands/Responses
B.3.1 Modulator Configuration Commands/Responses
B.3.1.1 Prime Modulator Active
Command:
<add/MA_x_yyy”cr”
Response:
>add/MA_x_yyy”cr”
Status Only:
<add/MA_x”cr”
Response:
>add/MA_x_yyy”cr””lf”]
Where:
x = 1 to 8 (prime modulator number).
yyy = YES or NO.
B.3.1.2 Prime Modulator Priority
Command:
<add/MP_x_y”cr”
Response:
>add/MP_x_y”cr””lf”]
Status Only:
<add/MP_x”cr”
Response:
>add/MP_x_y”cr””lf”]
Where:
x = 1 to 8.
y = 1, 2, or 3 (1 is high priority, 2 is medium priority, and 3 is low priority).
B.3.1.3 Prime Modulator Online Delay
Command:
<add/MD_x_yyy.y”cr”
Response:
>add/MD_x_yyy.y”cr””lf]
Status Only:
<add/MD_y”cr”
Response:
>add/MD_x_yyy.y”cr””lf]
Where:
x = 1 to 8 (prime modulator number).
yyy.y = .5 to 127 (time in increments of .5 seconds), or NONE.