Theory of Operation
SMS-758 Modem Protection Switch
4–44
MN/SMS758 Rev. 3
1
JP2
BACKUP
INTERFACE
SWITCH
AS/1694
15
16
.
JP1
1
2
. .
.
. . . . . . .
.
. . . . . . .
.
Figure 4-17. Backup IBS Jumper Diagram
Table 4-8. Backup IBS Jumpers
Operation
Jumper
Pins
Comments
Normal
JP1
5 through 6
7 through 8
13 through 14
15 through 16
Independent RST
and CTS
Special
JP1
1 through 2
3 through 4
9 through 10
11 through 12
CTS, tied to RTS,
TXD of ESC on
CTS lines
G.703
JP2
1 through 2
3 through 4
RS-422, V.35
JP2
No connections
No connections