B.3.5.8.3 M:N Switch Fault Status Summary
Command:
<add/MNF_”cr”
Response:
>add/MNF_”cr”
COM_FLT_xxxxxxxxByBy”cr”
Modem communications faults
(see Note)
MOD_CONFIG_FLT_xxxxxxxxByBy”cr”
Mod configuration verify faults
(see Note)
DMD_CONFIG_FLT_xxxxxxxxByBy”cr”
Demod configuration verify faults
(see Note)
MOD_COMPAT_FLT_xxxxxxxxByBy”cr”
Mod compatibility fault
(see Note)
DMD_COMPAT_FLT_xxxxxxxxByBy”cr”
Demod compatibility fault
(see Note)
+12V_FLT”cr”
power fault +12V
(see Note)
-12V_FLT”cr”
power fault -12V
(see Note)
+5V_FLT”cr”
power fault +5V
(see Note)
PS1_FLT”cr”
power supply #1 fault
(see Note)
PS2_FLT”cr”
power supply #2 fault
(see Note)
M&C_BAT_FLT”cr”
M&C battery fault
(see Note)
PARAMETER(S)_MISSING”cr””lf”]
Missing parameter fault; use “MPF”
command to determine faults
(see Note)
Where:
x = 1 to 8 (prime modem number).
y = 1 or 2 (backup modem number).
Note: Fault status data is only returned if fault conditions exist.
B.3.5.8.4 Missing Parameter Faults
Command:
<add/MPF_”cr”
Response:
>add/MPF_”cr”
NO_MOD_CONFIG_xxxxxxxxByBy”cr”
No mod configuration loaded
(see Note)
NO_DMD_CONFIG_xxxxxxxxByBy”cr”
No demod configuration loaded
(see Note)
NO_ADX_xxxxxxxxByBy”cr”
No address specified for modem
(see Note)
NO_INTFC_xxxxxxxxByBy”cr”
No interface specified for modem
(see Note)
NO_DL_xxxxxxxx”cr””lf”]
No downlink specified for demod
(see Note)
Where:
x = 1 to 8 (prime modem number).
y = 1 or 2 (backup modem number).