Remote Control Operation
SMS-758 Modem Protection Switch
B–16
MN/SMS758 Rev. 3
B.3.5.7.2 Verify Prime Modem Configuration
Command:
<add/VMC_x”cr”
Response:
>add/VMC_x”cr”
MOD_x_yyy”cr”
DMD_x_yyy”cr””lf”]
Where:
x = 1 to 8 (prime modem number).
yyy = OK or FLT.
B.3.5.7.3 Verify Backup Modem Configuration
Command:
<add/VMC_Bx”cr”
Response:
>add/VMC_Bx”cr”
MOD_Bx_yyy”cr”
DMD_Bx_yyy”cr””lf”]
Where:
x = 1 or 2 (backup modem number).
yyy = OK or FLT.
B.3.5.8 Operational Status Commands (Faults)
B.3.5.8.1 Modulator Operational Faults Status
Command:
<add/MOF_”cr”
Response:
>add/MOF_”cr”
BU_OP_FLT_xxxxxxxx”cr””lf”]
Backup operation faults
(see Note below)
Where: x = 1 to 8 (prime mod number).
Note: Fault status data is only returned if fault conditions exist.
B.3.5.8.2 Demodulator Operational Faults Status
Command:
<add/DOF_”cr”
Response:
>add/DOF_”cr”
BU_OP_FLT_xxxxxxxx”cr”
Backup operation faults
(see Note below)
DL_FLT_yyy”cr””lf”]
All Demods on downlink “y” faulted
(see Note below)
Where:
x = 1 to 8 (prime demod number).
y = 1, 2, 3 (faulted downlink number).
Note: Fault status data is only returned if fault conditions exist.